Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

FMR530 高精度雷达液位计

FMR530 高精度雷达液位计

Micropilot S FMR530

The Micropilot FMR530 is used for highly accurate non-contact level measurement in storage tanks and can be applied in custody transfer applications. It meets the relevant requirements according to OIML R85 and API 3.1B. The FMR530 free space radar offers cost-effective and simple installation via 4-wire cable with HART and 
24 V DC intrinsically safe power supply.
Compare

Continuous / Liquids

Measuring Principle
Supply / Communication 4-wire (HART)
Frequency C-band (~6 GHz)
Accuracy +/- 1 mm
Ambient temperature Standard:
-40 °C ... 80 °C
(-40 °F ... 176 °F)
For calibration to regulatory standards:
-25 °C ... 60 °C
(-13 °F ... 131 °F)
Process temperature -40 °C ... 200 °C
(-40 °F ... 392 °F)
Process pressure / max. overpressure limit Vacuum ... 64 bar
(Vacuum ... 580 psi)
Main wetted parts 316Ti
Process connection DN150 ... DN250 /3" ... 10"
Communication 4 ... 20 mA HART
Certificates / Approvals ATEX, FM, CSA, IEC Ex, NEPSI
Safety approvals Overfill prevention WHG
Marine approval GL/ ABS

Micropilot FMR530 is suitable for non-contact precision measurement of oil tank levels and can also be used for custody transfer measurement. FMR530 meets the relevant requirements of OIML R85 and API 3.1B. FMR530 uses four-wire technology with HART and 24 V DC intrinsically safe power supply, economical and easy to install.

 

Benefits

Accuracy: 0.5 mm (2σ value)

Custody transfer applications certified at national level (NMi and PTB)

The device can be used standalone or integrated into a tank level measurement system via the NRF590 tank-side indicator

Simple on-site operation via a menu-driven alphanumeric display module

FDT/DTM (FieldCare) software for convenient device commissioning, documentation and fault diagnostics

Antenna selected according to the application. Conical stilling wells are suitable for direct installation of the flat-face antenna

All antennas use a gas-tight process connection as standard (double safety)

 

Application

When the tank or nozzle geometry is not suitable for a parabolic antenna, a horn antenna can be used for free-space measurement (up to 25 m).

 

Process connection: flange

Temperature range: -40 to +200°C (-40 to +392°F)

Pressure range: -1 to +64 bar (-14.5 to +928 psi)

Maximum measuring range: 25 m (82 ft)

Accuracy: less than ±1 mm

C-band: 6 GHz

International explosion protection approval, custody transfer approval, WHG overflow protection, SIL, marine approval

 

 

E+H Product Configurator

Please enter the product model to configure

Product Comparison

Please enter the product models to compare in the fields below. Up to three products can be compared

 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

Source:Endress+Hauserwebsite public information

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Tank Farm Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Tank Farm Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Tank Farm Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Tank Farm Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Tank Farm.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Tank Farm for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.