Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

FQG61 Gamma射线仪表源盒

FQG61 Gamma射线仪表源盒

Source container FQG61

The FQG61 source container is designed to hold the radioactive source during radiometric point level detection, continuous level and density measurement. The radiation is emitted almost unattenuated in one direction only, and is damped in all other directions. This guarantees highest safety for the personnel and a reliable measurement.
Compare

Continuous / Liquids

Measuring Principle Radiometric
Characteristic / Application Source container
Emission angle: 40 / 20 degrees
Approximately 40kg
Specialities Manual or pneumatic switch-on/ switch-off
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

Continuous / Solids

Measuring Principle Radiometric
Characteristic / Application Source container
Emission angle: 40 / 20 degrees
Approximately 40kg
Specialities Control area calculation with Applicator
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

Density

Measuring Principle Radiometric Density
Characteristic / Application Source container
Emission angle: 5/ 20/ 40 degrees
Approximately 40kg
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure Any
Wetted parts Non-contact
Hygienic Non-contact
Specialities Control area calculation with Applicator

Point Level / Liquids

Measuring Principle Radiometric Limit
Characteristic / Application Source container
Emission angle: 5 degrees
Approximately 40kg
Specialities Control area calculation with Applicator
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

Point Level / Solids

Measuring Principle Radiometric Limit
Characteristic / Application Source container
Emission angle: 5 degrees
Approximately 40kg
Specialities Control area calculation with Applicator
Ambient temperature -40 °C...+200 °C
(-40 °F...+392 °F)
Process temperature Any
Process pressure / max. overpressure limit Any
Main wetted parts Non-contact
Process connection Non-contact
Certificates / Approvals ATEX, GOST

The FQG61 source capsule contains the radiation source and is used for radiometric limit detection as well as continuous level and density measurement. The radiation is emitted almost without attenuation in only one direction and is shielded in all other directions, ensuring maximum personnel safety and reliable measurement.

Benefits
Lightweight source capsule with near-spherical design for excellent shielding
Safe and convenient source replacement.
Meets the highest safety class (DIN 25426/ISO 2919, typical category C66646).
One-piece source capsule, simple installation.
Various radiation angles for optimum application results
Manual or pneumatic opening and closing
Switch position fixed by padlock, cylinder lock or safety bolt

Applications
Used to house the radiation source during radiometric limit detection, continuous level measurement and density measurement. The radiation is unattenuated in only one direction and damped in all other directions.
Activity: 137Cs... 18.5 GBq (500 mCi), 60Co ... 0.74 GBq (20 mCi)
Temperature: unrestricted (non-immersed, external measurement)
Pressure: unrestricted (non-immersed, external measurement)

 

E+H Product Model Configuration Tool

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source: Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Radiometric Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Radiometric.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Radiometric Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Radiometric.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Radiometric Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Radiometric.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Radiometric Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Radiometric.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Radiometric for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.