Solitrend MMP41
Technical Data
CompareMoisture in bulk solids
| Measuring Principle | Guided radar |
| Application | Moisture measurement in heterogeneous bulk solids with the density from 0.8...2 g/ cm³ like sand, gravel or gritt |
| Measuring method | Contact inline measurement |
| Measuring range | Recommended moisture range %/ vol.: 0...100 % |
| Material permeation depth | Up to 45 mm (0.15 ft) |
| Consistency of the sample | Conductivity range: 0…max. 5 mS/ cm |
| Temperature sensor | Yes |
| Process temperature | 0…+120°C (+32°F...+248°F) |
| Accuracy | Up to +/-0.1 % abs. |
| Output / communication | 0...20 mA 4...20 mA |
| Options | Remote display Sensor cables Baffle plate Universal holder Sliding carriage |
Our guided radar moisture sensors are highly wear-resistant and robust, minimizing the workload of secondary calibration, while real-time moisture measurement saves operating costs. Reliable moisture measurement helps improve product quality and reduce energy consumption.
Advantages
Easy commissioning even under demanding conditions
Strong material penetration (45 mm)
Wide moisture measuring range (0...100%)
Various installation accessories available
Remote electronics permit process temperatures up to 120°C
Built-in transmitter for convenient factory integration
Application areas
Moisture measurement of bulk solids with a medium density range of 0.8…2 g/cm3, e.g. sand, gravel, grit
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
A
A
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Humidity Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Humidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Humidity Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Humidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Humidity Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Humidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Humidity Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Humidity.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.