Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

MMP42 在线湿度测量仪

MMP42  在线湿度测量仪

Solitrend MMP42

Our guided radar moisture sensor is dedicated for lower moisture content. Optimize your process costs through reliable moisture measurement at any time and increase your product quality while reducing energy efforts
Compare

Moisture in bulk solids

Measuring Principle Guided radar
Application Moisture measurement in heterogenes bulk solids with the density from 0.3...1 g/ cm³ like animal food, grain, plastic granules and other pellets
Measuring method Contact inline measurement
Measuring range Recommended moisture range %/ vol.: 0...50 %
Material permeation depth Up to 60 mm (0.2 ft)
Consistency of the sample Conductivity range:
0…max. 2 mS/ cm
Temperature sensor Yes
Process temperature 0…+120°C
(+32°F...+248°F)
Accuracy Up to +/-0.1 % abs.
Output / communication 0...20 mA
4...20 mA
Options Remote display
Sensor cables
Baffle plate
Universal holder
Sliding carriage

Our guided radar moisture sensors are designed specifically for measuring lower moisture content. Reliable real-time moisture measurement helps optimize operating costs, improve product quality and reduce energy consumption.


Advantages
Easy commissioning even under demanding conditions
Strong material penetration (60 mm)
Wide moisture measuring range (0...100%)
Various installation accessories available
Remote electronics permit process temperatures up to 120°C
Built-in transmitter for convenient factory integration


Application areas
Moisture measurement of low-density bulk solids with a medium density of 0.3…1 g/cm3, e.g. pet food, grain, plastic granules and other pellets

 

E+H Product Model Configurator

Please enter the product model to configure

Product comparison

Please enter the product models to compare in the input fields below; up to three products can be compared

 

   

Technical documentation

   

Technical data

 

 

Documents / Manuals / Software

 

 

Accessories / Spare parts

 

A

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Humidity Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Humidity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Humidity Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Humidity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Humidity Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Humidity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Humidity Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Humidity.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Humidity for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.