Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TM121 热电阻温度计

TM121 热电阻温度计

iTHERM ModuLine TM121

Configurable Models 1 models
RTD or TC assembly characterized by basic sensor technology, application in non-hazardous areas, standard extension neck, low-cost unit. The devices are available with optional Bluetooth®-enabled head transmitters with 4 to 20 mA output or HART® communication, providing enhanced measurement accuracy and reliability compared to directly wired sensors.
Compare

Thermometer

Measuring Principle Resistance Temperature Detector
Characteristic / Application metric style
modular temperature assembly
universal range of application
with neck
incl. thermowell / protection tube (metal)
Thermowell / protection tube welded protection tube
Insert / probe Basis Sensortechnologie
Outer diameter protection tube / Insert Thermowell:
9x1,25 mm
11x2 mm
Max. immersion length on request up to 1.000,0 mm (39'')
Material protection tube/ thermowell 316L (1.4404)
Process connection Thread:
G1/2"
NPT1/2"
M20x1.5, M27x2, M33x2
Compression fitting:
NPT1/2", G1/2", G1"
Flansche:
DN25 DN40 B1
ASME 1" 150 RF
ASME 1" 300 RF
ASME 1 1/2" 150 RF
ASME 2" 150 RF
ASME 2" 300 RF
Tip shape straight
Operating temperature range Basic PT100 TF:
-50 °C …200 °C
(-58 °F …392 °F)
Typ K:
max. 1.100 °C
(max. 2.012 °F)
Max. process pressure (static) depending on the configuration
Accuracy Class A acc. to IEC 60751
Class B acc. to IEC 60751
Class standard acc. to ASTM E230
Class 2 acc. to IEC 60584-2
Response time t90 around 100 s
depending on configuration
Integration head transmitter yes (4 … 20 mA; HART)

RTD or TC assemblies feature basic sensor technology, are intended for use in non-hazardous areas, and have a standard extension neck and a low-cost design. These devices can be used with optional Bluetooth®-enabled transmitters with 4 to 20 mA output or HART® communication, providing higher measurement accuracy and reliability compared to directly connected sensors.

Benefits
Economical and reliable measurement
User-friendly interface, from product selection to maintenance
Wide range of process connections
Easy and safe device setup and maintenance via Bluetooth® communication

Application areas
Universal range
Applications in non-hazardous areas
Measuring range: –50 to +650 °C (–58 to +1202 °F)
Pressure range up to 50 bar (725 psi)
Degree of protection: up to IP 68

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source: public information from the Endress+Hauser website

Model Name
TM121-AACCB1A4GA2H1A1 热电阻温度计
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Thermocouple Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Thermocouple Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Thermocouple Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Thermocouple Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;