Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | US style modular temperature assembly for heavy duty applications suitable for hazardous areas threaded process connection to use with thermowell backlit display |
| Thermowell / protection tube | to use with thermowell |
| Insert / probe | mineral insulated (MI), flexible |
| Max. immersion length on request | up to 30.000,00 mm (1.181,10'') |
| Material protection tube/ thermowell | Not defined |
| Optional coating | Not defined |
| Process connection | male thread: G1/2" NPT1/2" NPT3/4" union nut: NPT1/2" M24x1.5 |
| Operating temperature range | PT 100: -200 °C ...600 °C (-328 °F ...1.112 °F) |
| Max. process pressure (static) | Depending on thermowell |
| Accuracy | class A acc. to IEC 60751 class AA acc. to IEC 60751 |
| Response time | depending on configuration t50 = 3 s t90 = 7 s |
| Integration head transmitter | yes (4 … 20 mA; HART) |
| Ex - approvals | ATEX II Explosion proof |
| Certification | Gost Metrology |
A specially designed, durable thermometer for safety-related, harsh applications in the chemical, oil, gas and energy industries. The thermometer has been extensively tested and fully approved to meet the relevant safety requirements. Using a temperature transmitter provides higher measurement accuracy and reliability than a directly wired sensor.
Advantages
HART® protocol, operated with a handheld terminal (DXR375) or remotely via PC
Rotatable illuminated display
Single Pt100 with 3-wire or 4-wire connection
Fast low-voltage response prevents output of incorrect measured values
Precise temperature measurement across the operating range
Approvals: ATEX (EEx ia, EEx d and dust protection, fire protection), CSA (IS, NI, XP, DIP)
Analog output
E+H Product Configurator
Please enter the product order code to configure
Product comparison
Please enter the order codes of the products to compare in the boxes below (up to three products)
Technical documentation
Technical data
Documents/Manuals/Software
Accessories/Spare parts
Source:Endress+Hauserwebsite public information
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Temperature Transmitter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Temperature Transmitter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Transmitter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Temperature Transmitter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Temperature Transmitter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Transmitter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Temperature Transmitter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Temperature Transmitter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Transmitter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Temperature Transmitter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Temperature Transmitter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Transmitter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauseriTEMP TMT72, Transmitter HART
Endress+HauseriTEMP TMT182, Head Transmitter HART
Endress+HauseriTEMP TMT82, Transmitter HART
Endress+HauseriTEMP TMT80, Head Transmitter
Endress+HauseriTEMP TMT71, Transmitter 4-20mA
Endress+HauseriTEMP TMT31, Transmitter 4-20mA
Endress+HauseriTEMP TMT142, Field Transmitter HART
Endress+Hauser