Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TWF11 High Temperature Ceramic Temperature Sleeve

TWF11 High Temperature Ceramic Temperature Sleeve

Thermowell TWF11

Suitable for basic industries such as steel treatment (heat treatment) and concrete incinerators with process temperatures up to+1600 ° C
Compare

Thermowell

Measuring Principle Fabricated Thermowell
Characteristic / Application metric style
Fabricated from segments
ceramic protection tube
process connection as compression fitting
Replacement part for TAF11
Head connection M24 x 1,5
groove for DIN A Head
Maximum standard immersion length 1.500 mm (59,06")
Max. immersion length on request 4.000 mm (157,48")
Process connection compression fitting:
G3/4"
G1"
G11/2"
adjustable Flange
Thermowell root diameter 14,0 mm (0,55")
16,0 mm (0,59")
17,0 mm (0,68")
22,0 mm (0,87")
24,0 mm (0,94")
26,6 mm (1,05")
Medium contact material Ceramic (C610)
silicon nitride ceramic (SiN)
sintered silicon carbide (SiC)
Tip shape straight
Temperature range -50...1650 °C (-58...3.002 °F)
Max. process pressure (static) 1 bar (15 psi)

Field of application
Process measuring points with extremely high temperatures require special ceramic thermowells. The thermowell made of special materials protects the sensor from mechanical and chemical damage during use and extends its service life. This results in lower maintenance costs for the measuring point, higher product quality and improved production safety. Specially designed, it serves as a replacement for the high-temperature TC thermometer TAF11 from Endress+Hauser.

Advantages
Innovative thermowell materials enhance wear and chemical corrosion resistance for a long service life
The sensor is protected by non-porous material for long-term stable measurement
Replaceable parts

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Temperature Sleeve Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Temperature Sleeve Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Temperature Sleeve Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Temperature Sleeve Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.