Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TU5200 台式浊度测定仪

TU5200 台式浊度测定仪

台式浊度测定仪

HACH TU5200
TU5200 浊度测定仪采用360°x90°光路系统,使该台式浊度仪在低量程测量中更准确。此款浊度测定仪支持单点校准,无需硅油擦拭样品瓶,支持以太网/USB链接,配置彩色触摸屏。

工作原理:

TU5200台式浊度测定仪采用360°x90°光路检测技术,激光照射样品中悬浮物颗粒,产生与入射光束呈90°的散射光,通过锥形反射镜后360°环绕样品,然后被透射光检测器检测到。散射光强度与悬浮物颗粒成正比,TU5200浊度测定仪通过测量悬浮物颗粒产生的散射光强度测定浊度。

应用行业:

TU5200 台式浊度测定仪适用于自来水,电力,饮料,制药等领域。

仪器特点:

● TU5200台式浊度测定仪采用特有的360° x 90°光路设计和检测技术,确保低浊度测量的高准确度。

● 在0–40 NTU范围内支持单点校准,简化台式浊度仪的校准工作。

● TU5200台式浊度测定仪无需使用硅油和油布擦拭样品瓶,降低人为误差。

● 台式浊度仪配备以太网接口和USB接口,可连接网络或外部设备实现数据输入输出及打印等功能。

● 台式浊度仪配备7寸彩色触摸屏,中文界面更直观,操作更便捷。

● TU5200台式浊度测定仪可设置不同等级的加密权限,保证测试的安全性。

技术规格
光源                     650 nm (EPA) 或 850 nm (ISO),最大 1 mW 。2 类激光产品:包含非用户可维修 2 类激光。依据激光公告第 50 条,本产品符合 IEC/EN 60825-1 和 21 CFR1040.10 。
量程                     EPA: 0 至 700 NTU、FNU、TE/F、FTU;0 至 100 mg/L;0 至 175 EBC
                            ISO: 0 至 1000 NTU / FNU / TE/F / FTU;0 至 100 mg/L;0 至250 EBC
准确度                 0 至 40 NTU 读数的±2% 加 0.01 NTU
                           根据 Formazin 主要标准,在 25 °C (77 °F) 下,40 至 700 NTU 时,读数的 ± 10%
分辨率                 0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
重复性                根据 Formazin 主要标准,在 25°C (77°F) 下,< 40 NTU: 0.002 NTU 或读数的 1% (取更大值);> 40 NTU: 优于读数的3.5%
杂散光                < 10 mNTU
测量单位             NTU、FNU、TE/F、FTU、EBC、mg/L、mNTU、mFNU
工作温度             10 至 40 °C(50 至 104°F)相对湿度 5 至 95%,无冷凝
电源要求(电压)    100 - 240 VAC
电源要求(Hz)       50/60 Hz

订购指南
TU5200实验室激光浊度仪
LPV442.99.01012    TU5200实验室激光浊度仪,650nm,EPA版本
LPV442.99.01022    TU5200实验室激光浊度仪,850nm,ISO版本
校准和校验
LZY898    StablCal校准套装
LZV946    TU5200样品瓶
附件
LZY903    TU5200/TU5300sc/TU5400sc 手动小瓶擦拭器
LZQ165    硅胶小瓶擦拭器,自动清洁模块
LZQ176    纤维小瓶擦拭器,自动清洁模块


来源:哈希水质网站公开信息

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Hach-Lab Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Hach-Lab Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Hach-Lab Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Hach-Lab Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Hach-Lab.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Hach-Lab for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.