CLM253 Transmitter Spare Parts Overview

CLM253 is a commonly used transmitter in industrial process analysis, and its spare parts management is crucial for maintenance efficiency. This spare parts list lists the main spare parts and their order numbers, covering panels, modules, power supplies, etc., facilitating quick selection by users. Correct selection of spare parts can reduce downtime and ensure measurement accuracy.

Spare Parts List

Order NumberSpecification DescriptionRemarks
51501068KIT CXM253 housing cover / KIT CXM253 housing coverSuitable for 410, 420, 46
71071446Kit CxM253: Front foil + 6 key lifters335
51501073CXM253 Internal housing parts / KIT CXM253 Internal housing parts330, 340, 45
51502184Transmitter connection head
51501072CXM253 bottom of housing / KIT CXM253 bottom of housing400
51501069KIT hinges / KIT hinges430
51501087CXM253 Ground terminal strip / KIT CXM253 Ground terminal strip403
51501079CXM223 terminal strip power supply / KIT CXM253 terminal strip power supply470
50086842LIQUISYS transmitter column mounting kitFor horizontal or vertical pipe mounting (max. diameter 60mm), material: stainless steel V2A
51501074CXM253 Ribbon cables / KIT CXM253 Ribbon cables310
51501210CLM2x3 Central module I1 conductive / KIT CLM2x3 Central module I1 conductive40
51501213CLM2X3 Conductive module I1 HART / KIT CLM2X3 Conductive modul I1 HART60
51501212CLM2X3 Conductive module I2 / KIT CLM2X3 Conductive module I250
51501214CLM2X3 Conductive module I2 HART / KIT CLM2X3 Conductive module I2 HART70
51501215CLM2X3 central module Profibus PA cond. / KIT CLM2X3 cen. module Profibus PA cond.80
51502502Kit CLM2X3 central module Profibus DP kond / Kit CLM2X3 central module ProfibusDPkond90
71134726Kit CLM2x3: Centralm. cond. PBDP;H/W2.1xContents: 1x Central module Profibus DP, module name: LSCP-DP, certified from H/W 2.10
71134732Relay moduleContents: 1x Relay module Profibus DP, 2x Relay, 1x Current input DP connection, certified from H/W 2.10
51501216CLM2x3 inductive module I1 / KIT CLM2x3 inductive module I140
51501219CLM2x3 Inductive module I1 HART / KIT CLM2x3 Inductive modul I1 HART60
51501218CLM2x3 Inductive module I2 / KIT CLM2x3 Inductive module I250
51501220CLM2x3 Inductive module I2 HART / KIT CLM2x3 Inductive module I2 HART70
51501221CLM2X3 central module Profibus PA ind / KIT CLM2X3 cen. module Profibus PA ind80
51502501Kit CLM2X3 central module Profibus DP ind / Kit CLM2X3 central module Profibus DPind90
71134727Kit CLM2x3: Centralm. ind. PBDP; H/W2.1xContents: 1x Central module Profibus DP, module name: LSCP-DP, certified from H/W 2.10
71161133Transmitter board240
51500317CXM2X3 power supply AC / KIT CXM2X3 power supply AC15
51500318CXM2X3 power supply DC / KIT CxM2x3 power supply DC20
51511446Relay moduleUpgrade LIQUISYS-M basic version with 2 floating changeover contacts
51500320Relay output moduleUpgrade LIQUISYS-M basic version with 2 floating changeover contacts
51500321Relay output circuit boardUpgrade LIQUISYS-M basic version with 4 floating changeover contacts
51511447Relay module300
51504304Relay output moduleUpgrade LIQUISYS-M basic version with 2 contacts and current input 4-20mA
51504305Relay output moduleUpgrade LIQUISYS-M basic version with 4 contacts and current input 4-20mA
51500385"Extended software" upgrade packageUpgrade LIQUISYS-M basic version to S version (plus-package), supports parameters pH, Cond., Tu, CL, O2 (WX to WS), requires instrument serial number
51500963"Cleaning function" upgrade packageAdds cleaning function (Chemoclean) to LIQUISYS-M basic version, requires instrument serial number. If the 4-relay board is not yet installed, it must be ordered separately (51500321)

Spare Parts Selection Guide

Module Selection

The CLM2x3 series modules are divided into conductive and inductive types, each with I1, I2, and HART versions. Selection should be determined based on the measurement principle and communication requirements. For example, conductive modules are suitable for conductivity measurement, while inductive modules are suitable for electromagnetic conductivity measurement. The HART version supports the HART communication protocol.

Power Supply Selection

Select an AC or DC power supply module according to the on-site power supply conditions. Order number 51500317 is an AC power supply, and 51500318 is a DC power supply. Ensure that the power supply voltage matches the transmitter requirements.

Relay Module Selection

Relay modules are used for alarm or control outputs. The basic version can add relay outputs through upgrade packages. Order number 51500321 provides 4 floating changeover contacts, while 51504304 and 51504305 also include 4-20mA current input. When selecting, consider the required number of contacts and input type.

Upgrade Package Selection

The "Extended software" upgrade package (51500385) can upgrade the LIQUISYS-M basic version to the S version, adding measurement functions for parameters such as pH, conductivity, temperature, residual chlorine, and oxygen. The "Cleaning function" upgrade package (51500963) adds the Chemoclean cleaning function and must be used with the 4-relay board.

Installation and Maintenance Precautions

  • Before installation, please confirm that the spare parts are compatible with the transmitter model.
  • When replacing modules, please disconnect the power supply and follow anti-static precautions.
  • When upgrading software or functions, the instrument serial number must be provided.
  • Regularly check the ground terminal strip and cable connections to ensure reliability.

For more technical information, please refer to the official documentation or contact technical support.