CCS140 Series Spare Parts Overview

The CCS140 series analyzers are widely used in water quality monitoring and industrial process control. To ensure long-term stable operation of the equipment, regular replacement of spare parts is crucial. This article compiles the CCS140 spare parts list, including key components such as measuring chambers, seals, membranes, electrolytes, maintenance kits, junction boxes, measuring cables, and calibration instruments, for reference by engineering technicians and procurement.

Core Spare Parts List and Specifications

The following table summarizes the main spare parts for the CCS140 series, including order numbers, specifications, and applicable models. Please select the corresponding parts according to actual needs.

No. Order No. Specification Description Applicable Model/Remarks
1 71268479 Kit CCSx4x/142D: Measuring chamber CCS140/141/240/241
2 71268482 CCSx4x/142D spare parts: Seals x2 CCS140/141/240/241
A 50005255 Membrane replacement parts, 2 pcs., ready made for CCS 140/141/240/241
50005256 Electrolyte, 50 ml CCS 140/141
A 71076921 Maintenance kit CCS14x Includes 50ml electrolyte, 2 membrane caps, polishing foil (2 qualities)
50005181 Junction box VBC For extending CMK measuring cable, protection class IP65
50085333 Measuring cable For pH/redox electrodes or 2-electrode conductivity cells/2-electrode current cells, with temperature sensor, priced per meter (minimum length 5 meters)
71257946 Handheld DPD colorimetric calibration instrument PF-3 Colorimetric measurement of free chlorine and total chlorine, 0.05-6mg/l, IP67, compliant with ISO 7393, includes carrying case and test kit
COY8- Zero-point gel COY8 For zero-point verification, calibration, and adjustment of oxygen and disinfection sensors, suitable for amperometric and optical sensors, diameter 12/25/40mm, laboratory and field applications

Detailed Explanation of Key Spare Parts

Measuring Chamber and Seals

Measuring chamber (Order No. 71268479) is the core component of the CCS140 series, directly contacting the sample, and requires regular inspection or replacement. The accompanying seals (Order No. 71268482) include 2 pieces per set, ensuring the sealing of the measuring chamber and preventing leakage.

  • Measuring chamber: Kit CCSx4x/142D, suitable for CCS140/141/240/241.
  • Seals: CCSx4x/142D spare parts, 2 pieces per set.

Membranes and Electrolyte

Membrane replacement parts (Order No. 50005255) include 2 pieces per set, pre-formed, suitable for CCS 140/141/240/241. Membranes need regular replacement to ensure measurement accuracy. Electrolyte (Order No. 50005256) has a capacity of 50ml, specifically for CCS 140/141, and needs to be replenished simultaneously when replacing membranes.

Maintenance Kit

Maintenance kit CCS14x (Order No. 71076921) includes 50ml electrolyte, 2 membrane caps, and polishing foil (2 qualities), making it a convenient choice for daily maintenance. It is recommended to replace regularly according to usage frequency.

Junction Box and Measuring Cable

Junction box VBC (Order No. 50005181) is used to extend CMK measuring cables, with protection class IP65, suitable for harsh environments. Measuring cable (Order No. 50085333) is suitable for pH/redox electrodes or 2-electrode conductivity cells/2-electrode current cells, with temperature sensor, priced per meter, minimum length 5 meters.

Calibration and Verification Tools

Handheld DPD colorimetric calibration instrument PF-3 (Order No. 71257946) is used for colorimetric measurement of free chlorine and total chlorine, range 0.05-6mg/l, protection class IP67, compliant with ISO 7393 standard. Suitable for disinfection, drinking water, and process water, it is an ideal tool for calibrating and verifying disinfection loops.

Zero-point gel COY8 is used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors, suitable for amperometric and optical sensors, diameter 12/25/40mm, can be used in laboratory and field.

Selection and Procurement Recommendations

When purchasing CCS140 spare parts, please confirm the equipment model and required components. It is recommended to regularly check the status of the measuring chamber, seals, and membranes, and stock common maintenance kits. For cables and junction boxes, pay attention to protection class and length requirements. Calibration instruments and zero-point gel are key tools to ensure measurement accuracy, and it is recommended to configure them as needed.

  • Confirm model compatibility: Some spare parts are common to CCS140/141/240/241.
  • Pay attention to protection class: e.g., IP65 junction box, IP67 calibration instrument.
  • Purchase as needed: Electrolyte and membranes have specific applicable models.