CCS51D Spare Parts List Overview

The CCS51D is a sensor widely used in disinfection, drinking water, and process water monitoring. To ensure its long-term stable operation, regular replacement of spare parts is essential. The table below summarizes commonly used spare parts and their order numbers for quick reference and procurement.

Adapter Kits

Adapter kits are used to connect CCS5x and CCS5xD sensors to different types of holders or flow assemblies. Selecting the appropriate kit based on the application ensures secure installation and reliable sealing.

Optional Adapter Kits

  • Order No. 71372025: CCA250 adapter kit, suitable for CCS5x + CCS5xD sensors.
  • Order No. 71372026: CYA112 adapter kit, suitable for CCS5x + CCS5xD sensors.
  • Order No. 71372027: CCA151 adapter kit, suitable for CCS5x + CCS5xD sensors, including retaining ring, thrust ring, and sealing ring.
  • Order No. 71554885: Adapter kit CCS5x(D/E), for CYA27-xxxB* models.

The following is a detailed specification comparison of some adapter kits:

Order No. Specification Description Included Components
71372025 CCA250 adapter kit CCS5x + CCS5xD
71372026 CYA112 adapter kit CCS5x + CCS5xD
71372027 CCA151 adapter kit CCS5x + CCS5xD Retaining ring, thrust ring, sealing ring
71554885 Kit adapter CCS5x(D/E) for CYA27-xxxB*

DPD Colorimetric Calibration Instrument

The handheld DPD colorimetric calibration instrument PF-3 is used for calibration and verification of disinfection loops, enabling precise measurement of free chlorine and total chlorine. It complies with ISO 7393 and is suitable for on-site and laboratory environments.

PF-3 Technical Parameters

  • Measurement Principle: DPD colorimetric method, compliant with ISO 7393
  • Measurement Range: 0.05 - 6 mg/l (free chlorine and total chlorine)
  • Protection Rating: IP67
  • Application Areas: Disinfection, drinking water, and process water
  • Scope of Delivery: Handheld photometer, cuvettes, DPD reagents, plastic case, test kit

This calibration instrument is an indispensable tool for maintaining disinfection loops, helping you quickly troubleshoot issues and ensure measurement accuracy.

Maintenance Kits

Regular maintenance extends sensor life and ensures measurement accuracy. The CCV05 maintenance kit is designed for Memosens CCSxxD sensors such as the CCS51D, and includes key components required for fixed-cable sensors CCSxx.

  • CCV05-: Maintenance kit, suitable for Memosens CCSxxD and fixed-cable sensors CCSxx.

It is recommended to establish a maintenance plan based on usage frequency and environmental conditions, and replace worn parts promptly.

Zero-Point Gel

COY8 zero-point gel is used for zero-point verification, calibration, and adjustment of oxygen and disinfection sensors. It is suitable for amperometric and optical sensors, providing a reliable zero-point reference.

COY8 Features

  • Applicable Sensors: Amperometric and optical sensors
  • Diameter Compatibility: 12 mm, 25 mm, 40 mm
  • Application Scenarios: Laboratory and on-site
  • Function: Zero-point verification, calibration, adjustment

Using zero-point gel ensures sensor accuracy at low concentration measurements and is an important part of the maintenance process.

Selection and Procurement Recommendations

Select the appropriate spare parts based on your specific application and sensor model. The following steps are recommended:

  1. Confirm the sensor model (e.g., CCS51D) and the required spare part type.
  2. Select the adapter kit based on the installation method (e.g., CCA250, CYA112, etc.).
  3. For regular calibration, it is recommended to equip the PF-3 calibration instrument and COY8 zero-point gel.
  4. Procure CCV05 maintenance kits according to the maintenance cycle.

Proper selection can reduce downtime and improve measurement reliability. For more information, please consult our technical support team.