Nr
Order No.
Specification
F
50096745
Power board 50/51/53 85-260VAC
Kit power s.b. PMAG5X 85-260VAC
F
71039466
Power board
HE = harsh environment
F
71039466
Power board
HE = harsh environment
F
50096746
Power board PMAG5X 85-260VAC Ex
F
71039467
Power board
HE = harsh environment
F
50096747
Power board electromagnetic 50/51/53 20-55VAC 16-62VDC
F
71039468
Power board
HE = harsh environment
F
50096744
50/51/53 power board 20-55VAC 16-62VDC Ex
F
71039469
Power board
HE = harsh environment
7
50094002
10 pcs 800mA fuse
Kit 10 fuses 250 VAC T800 MA
7
50094003
10 pcs 2A fuse
Kit Bus/connec.b.5X/40/8X/65 field hous.
B
50106079
Amplifier board
Language: FR, ES, IT, NL, PT, DE, EN
B
71039448
Amplifier board
Language: FR, ES, IT, NL, PT, DE, EN
HE = harsh environment
B
50106081
Amplifier board
Language: JA, ID, EN
B
71039450
Amplifier board
Language: JA, ID, EN
HE = harsh environment
B
50106080
Amplifier board
Language: SV, FI, NO, RU, PL, CS, EN
B
71039449
Amplifier board
Language: SV, FI, NO, RU, PL, CS, EN
HE = harsh environment
B
50106076
Amplifier board
Language: FR, ES, IT, NL, PT, DE, EN
B
71039451
Amplifier board
Language: FR, ES, IT, NL, PT, DE, EN
HE = harsh environment
B
50106073
Signal amplifier module
Language: FR, ES, IT, NL, PT, DE, EN
B
71039445
Amplifier board
Language: FR, ES, IT, NL, PT, DE, EN
HE = harsh environment
B
50106078
Amplifier board
Language: JA, ID, EN
B
71039453
Amplifier board
Language: JA, ID, EN
HE = harsh environment
B
50106075
PMAG 50 amplifier spare parts
Language: JA, ID, EN
B
71039447
Amplifier board
Language: JA, ID, EN
HE = harsh environment
B
50106077
Amplifier board
Language: SV, FI, NO, RU, PL, CS, EN
B
71039452
Amplifier board
Language: SV, FI, NO, RU, PL, CS, EN
HE = harsh environment
B
50106074
PMAG 50 amplifier
Language: SV, FI, NO, RU, PL, CS, EN
B
71039446
Amplifier board
Language: SV, FI, NO, RU, PL, CS, EN
HE = harsh environment
C
50098302
5X/40/8X/93/65 output module
Kit com5X/40/8X/93/65 Iout pass/Freq.Exi
C
71039479
Input/output board
50/53/8X
HE = harsh environment
C
50098303
5X/40/8X/93/65 output module
Kit com5X/40/8X/93/65 Iout act/Freq.Exi
C
71039478
Input/output board
50/53/8X
HE = harsh environment
C
50096759
50/51/40/80/90 Ex output module
Kit com50/51/40/80/90 I+F/stat.in+outEx
C
71039473
Input/output board
HE = harsh environment
C
50096757
50/40/80/90 Ex current/frequency output module
Kit com50/40/80/90 curr/Freq.out Ex
C
71039474
Input/output board
HE = harsh environment
C
71066579
Input/output board PA Ex
50/53/55/80/83/93/65
C
71066580
Input/output board
HE = harsh environment
C
50096756
Pline 50/90 Ex current output module
Kit com Pline 50/90 current out Ex
C
71039710
I/O current output
HE = harsh environment
C
71021742
Communication module
C
71039484
Input/output board
HE = harsh environment
E
50108132
50/51/80/65 display module higher than version 1.06.00
Kit display mod 50/51/80/65 >=V1.06.00
J
50108131
Wall-mount display module above 1.06.00
Kit disp.50/51/80/90/65 Wall >=V1.06.00
21
50094017
5X/8X/9X/65 wall-mount bus interface
Kit Bus PCB/PCB carr.5X/8X/9X/65 wall
H
50099099
5X/8X stainless steel housing bus wiring module
G
50094016
5X/40/8X/65 field-mount bus interface
19
50094015
Wall-mount wiring module
19
71039496
Wall-mount terminal board
HE = harsh environment
18
50094014
Wall-mount wiring module
Kit connec. board In/Output Wall encl
29
50108139
5X/8X/40/65 field-mount terminal block
Kit Termin.Block field hous. 5X/8X/40/65
30
50108140
5X/8X/9X/65 wall-mount terminal block
Kit Termin.Block Wall encl. 5X/8X/9X/65
S
71003946
S-Data module with setting
Serialnumber is forceful required
17
50099100
5X/8X stainless steel housing glass cover
8
50094027
5X/40/8X/93/65 Ex glass cover
Kit Cover 5X/40/8X/93/65 with window Exd
8
50094026
5X/40/8X/65 glass cover
Kit Cover 5X/40/8X/65 with window
9
50094029
5X/40/8X/93/65 Ex blind cover
Kit Cover 5X/40/8X/93/65 vers. blind Exd
9
50094028
5X/40/8X/65 blind cover
Kit Cover 5X/40/8X/65 version blind
10
50094040
Flameproof terminal compartment cover
Kit Cover 5X/40/8X/93/65 Conn.termi.Exd
10
50094039
Increased safety terminal compartment cover
Kit Cover 5X/40/8X/93/65 Conn.termi.Exe
10
50094038
Terminal compartment cover
10/5X/40/8X/93/65/92F
71309084
Housing repair G04
Usage: 10H,50H,53H,55H
15
50098036
10 pcs M20x1.5 Ex cable glands
Kit 10 cable glands M20x1.5 Ex
15
50098036
10 pcs M20x1.5 Ex cable glands
Kit 10 cable glands M20x1.5 Ex
15
50098036
10 pcs M20x1.5 Ex cable glands
Kit 10 cable glands M20x1.5 Ex
15
50096840
10 pcs M20x1,5 cable glands
Kit 10 cable glands M20x1,5
15
50098040
M20x1.5/PG13,5 adapter
15
50098042
M20x1.5/NPT 1/2" adapter
Kit 10 extension M20x1.5/NPT 1/2"
15
50098042
M20x1.5/NPT 1/2" adapter
Kit 10 extension M20x1.5/NPT 1/2"
15
50098041
M20x1.5/G 1/2" adapter
Kit 10 extension M20x1.5/G 1/2"
15
50098041
M20x1.5/G 1/2" adapter
Kit 10 extension M20x1.5/G 1/2"
15
50098037
PA bus cable gland
Kit Cable gland Profibus PA
Kit 10 extension M20x1.5/PG13,5
12
50096839
Circuit board bracket (field/stainless steel housing)
Kit Circuit board cpl field/SS-housing
14
50099102
Cast aluminum/stainless steel housing sleeve
13
50096841
Ground terminal/cover clamp
Kit Ground terminal / Cover clamp
16
50099101
Stainless steel housing seal ring
20
50094041
Wall-mount sealing cover
Kit Seal cover to Wall enclosure
11
50094050
Field-mount sealing cover
Kit 10 Seal cover to field housing
23
50098020
Mounting screws and mounting accessories
Usage:
10/23/50/51/53/55
Sensor: D/E/H/L/P/S/W
25
50098019
Mounting screws and mounting accessories
Usage:
10/50/51/53/55/400/800
Sensor: D/E/H/L/P/S/W
22
50098021
Washer
24
50098022
Washer
71129286
Special screw M6
M6x16/5,0 6kt, ISO4017 A2
DK5CA-
Promag 10/50/51/53/55 remote version cable DK5CA
10/50/51/53/55/400/800
1 kit includes 1 coil cable and
1 signal cable
Cable, Remote Version:
1
5m/15ft
2
10m/30ft
4
..... m
5
..... ft
Approval:
A
Non-hazardous area + ATEX II 3G, FM/CSA
B
ATEX II2GD, TIIS Zone 1
50XXX-
**Promag 50 transmitter 50XXX
Application:
XXX
Promag 50W, 50P, 50H, 50D, 50L, 50E
Version:
XX
Transmitter only
Approval:
A
Non-hazardous area
B
ATEX II 2GD+ IECEx Z1,21; Ex d wiring, Ex deia IIC, Ex tD A21 Z=Zone
D
ATEX II 2GD+ IECEx Z1,21; Ex e wiring, Ex deia IIC, Ex tD A21 Z=Zone
J
ATEX II 3G Ex nA nC IIC
N
FM XP Cl. I Div. 1 / CSA Cl. I Div. 1
R
FM NI Cl. I Div. 2 / CSA Cl. I Div. 2
Housing:
1
Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
2
Compact stainless, IP67 NEMA4X, -40oC/oF Sensor see specification
3
Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
9
Special version, TSP-no. to be spec.
A
Compact Alu, IP67 NEMA4X
B
Compact stainless, IP67 NEMA4X
C
Wall Alu, IP67 NEMA4X
G
Field Alu, IP67 NEMA4X
P
Compact Alu, IP67 NEMA4X, HE HE= harsh environment
R
Compact stainless, IP67 NEMA4X, HE HE= harsh environment
S
Wall Alu, IP67 NEMA4X, HE HE= harsh environment
T
Field Alu, IP67 NEMA4X, HE HE= harsh environment
Cable, Remote Version:
0
Not used
1
5m/15ft coil and signal cable
2
10m/30ft coil and signal cable
4
..... m coil and signal cable
5
..... ft coil and signal cable
9
Special version, TSP-no. to be spec.
Cable Entry:
9
Special version, TSP-no. to be spec.
A
Gland M20 (EEx d > thread M20)
B
Thread NPT 1/2
C
Thread G 1/2
K
Bus plug + gland M20
L
Bus plug + thread NPT 1/2
M
Bus plug + thread G 1/2
Power Supply; Display:
7
85-260VAC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL
8
20-55VAC / 16-62VDC, WEA, w/o display, Remote configuration WEA= language DE+EN+FR+IT+ES+PT+NL
9
Special version, TSP-no. to be spec.
A
85-260VAC, WEA, 2-line + push buttons, WEA= language DE+EN+FR+IT+ES+PT+NL
B
20-55VAC / 16-62VDC, WEA, 2-line + push buttons, WEA= language DE+EN+FR+IT+ES+PT+NL
C
85-260VAC, SEA, 2-line + push buttons, SEA= language JA+ID+EN
D
20-55VAC / 16-62VDC, SEA, 2-line + push buttons, SEA= language JA+ID+EN
E
85-260VAC, EES, 2-line + push buttons, EES= language SV+FI+NO+RU+PL+CS+EN
F
20-55VAC / 16-62VDC, EES, 2-line + push buttons, EES= language SV+FI+NO+RU+PL+CS+EN
Adjustment; Software Feature:
A
Factory setup; basic version
C
Factory setup; ECC electrode cleaning circuit
Output, Input:
A
4-20mA SIL HART + frequency
D
4-20mA SIL HART + freq.+ status+stat.In
H
PROFIBUS PA
J
PROFIBUS DP
S
4-20mA SIL HART active + freq., Ex-i, freq. = passive
T
4-20mA SIL HART passive + freq., Ex-i, freq. = passive
W
4-20mA SIL HART
DK5WM-
Promag10/50/51/53/55 transmitter mounting kit DK5WM
10/50/51/53/55/800
Application:
A
Remote, wall / pipe mounting, panel
B
Remote, field Tube 3/4 - 3inch
50H-
**Electromagnetic flowmeter 50H
Electromagnetic flowmeter
PFA liner
Nominal diameters
02
DN02 1/12"
04
DN04 5/32"
08
DN08 5/16"
15
DN15 1/2"
1F
DN150 6"
1H
DN100 4"
1Z
DN125
22
DN25 1" ODT, SMS, ANSI, ISO pipes
26
DN25 DIN, JIS pipes
40
DN40 1 1/2"
50
DN50 2"
65
DN65 2 1/2"
80
DN80 3"
Process Connection:
0
Clamp DIN32676, 316L/1.4404
1
Tri-Clamp, 316L/1.4404
2
DIN11851, 316L/1.4404
3
Aseptic DIN11864-1A, 316L/1.4404
4
Aseptic DIN11864-2A, 316L/1.4404
5
SMS1145, 316L/1.4404
6
ISO2853, 316L/1.4404
9
Special version, TSP-no. to be spec.
A
Not used
B
Welding nipple EN ISO1127, 316L/1.4404
C
Welding nipple ODT/SMS, 316L/1.4404, O= O-ring
D
PN40, 316L/1.4404, flange EN1092-1
E
Cl.150, 316L/1.4404, flange ANSI B16.5
F
20K, SUS 316L, flange JIS B2220
G
PN16, PVDF, flange EN1092-1 (DIN2501)
H
Cl.150, PVDF, flange ANSI B16.5
J
10K, PVDF, flange JIS B2220
K
Male thread ISO228, 316L/1.4404
L
Female thread ISO228, 316L/1.4404
M
Hose adapter ID=13mm, 316L/1.4404
N
Hose adapter ID=16mm, 316L/1.4404
P
Hose adapter ID=19mm, 316L/1.4404
R
Adhesive fitting tube 1/2", PVC
S
Adhesive fitting 20x2mm tube, PVC
W
Clamp ISO2852, 316L/1.4404
Seal:
0
Not used
9
Special version, TSP-no. to be spec.
A
O-ring, EPDM
B
O-ring, Viton
C
O-ring, Kalrez
F
Aseptic shape, EPDM
G
Aseptic shape, Viton
H
Aseptic shape, Silicone
Electrodes:
0
1.4435/316L
1
Alloy C-22
2
Tantalum
5
Platinum
9
Special version, TSP-no. to be spec.
A
1.4435/316L + grounding rings
B
Alloy C-22 + grounding rings
D
Tantalum + grounding rings
G
1.4435/316L, bullet nose
Calibration:
9
Special version, TSP-no. to be spec.
A
0.5%
B
0.2%
D
0.5%, 3-point, traceable ISO/IEC17025
E
0.2%, 3-point, traceable ISO/IEC17025
Additional Test, certificate:
1
w/o
2
Mat. certificate (flange)
3
pressure test
4
Mat. certificate (flange) + pressure test
5
CRN approval
8
CRN approval + mat. certicate (flange) + pressure test
9
Special version, TSP-no. to be spec.
E
EAC marking
N
EAC marking + mat. certificate (flange)
P
PED Cat. II/III
R
PED Cat. II/III + mat. certificate (flange)
Approval:
A
Non-hazardous area
B
ATEX II 2GD+ IECEx Z1,21; Ex d wiring, Ex deia IIC, Ex tD A21 Z=Zone
D
ATEX II 2GD+ IECEx Z1,21; Ex e wiring, Ex deia IIC, Ex tD A21 Z=Zone
J
ATEX II 3G Ex nA nC IIC
K
NEPSI Ex de IIC, wiring Ex d
N
FM XP Cl. I Div. 1 / CSA Cl. I Div. 1
R
FM NI Cl. I Div. 2 / CSA Cl. I Div. 2
S
NEPSI Ex de IIC, wiring Ex e
U
TIIS Zone 1
Housing:
1
Compact Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
2
Compact stainless, IP67 NEMA4X, -40oC/oF Sensor see specification
3
Wall Alu, IP67 NEMA4X, -40oC/oF Sensor see specification
4
Compact stainless + Polycarbonate window, IP67 NEMA4X
9
Special version, TSP-no. to be spec.
A
Compact Alu, IP67 NEMA4X
B
Compact stainless, IP67 NEMA4X
C
Wall Alu, IP67 NEMA4X
G
Field Alu, IP67 NEMA4X
P
Compact Alu, IP67 NEMA4X, HE HE= harsh environment
R
Compact stainless, IP67 NEMA4X, HE HE= harsh environment
S
Wall Alu, IP67 NEMA4X, HE HE= harsh environment
T
Field Alu, IP67 NEMA4X, HE HE= harsh environment
Cable, Remote Version:
0
Not used
1
5m/15ft coil and signal cable
2
10m/30ft coil and signal cable
4
..... m coil and signal cable
5
..... ft coil and signal cable
9
Special version, TSP-no. to be spec.
Cable Entry:
9
Special version, TSP-no. to be spec.
A
Gland M20 (EEx d > thread M20)
B
Thread NPT 1/2
C
Thread G 1/2
E
Gland G 1/2", Ex d Shimada
K
Bus plug + gland M20
L
Bus plug + thread NPT 1/2
M
Bus plug + thread G 1/2
X
Not used, sensor only
Power Supply; Display:
9
Special version, TSP-no. to be spec.
X
Sensor only
Adjustment; Software Feature:
9
Special version, TSP-no. to be spec.
X
Sensor only
Output, Input:
9
Special version, TSP-no. to be spec.
X
Sensor only
>Design:
CA
Process connection short
>>Marking:
Z1
Tagging (TAG), see additional spec.
Z2
Bus address, see additional spec.
DKH-
Promag H mounting kit DKH
A set includes 2 process connections
and 2 seals.
Nominal Diameter:
02
DN02 1/12"
04
DN04 5/32"
08
DN08 5/16"
15
DN15 1/2"
1F
DN150 6"
1H
DN100 4"
1Z
DN125
22
DN25 1" ODT, SMS, ANSI, ISO pipes
26
DN25 DIN, JIS pipes
40
DN40 1 1/2"
50
DN50 2"
65
DN65 2 1/2"
80
DN80 3"
Process Connection:
99
Special version, TSP-no. to be spec.
AA
Welding nipple EN ISO1127, 316L/1.4404
AB
Welding nipple ODT/SMS, 316L/1.4404, O= O-ring
FA
PN40, 316L/1.4404, flange EN1092-1
FB
Cl.150, 316L/1.4404, flange ANSI B16.5
FC
20K, SUS 316L, flange JIS B2220
FD
PN16, PVDF, flange EN1092-1 (DIN2501)
FE
Cl.150, PVDF, flange ANSI B16.5
FF
10K, PVDF, flange JIS B2220
GA
Male thread ISO228, 316L/1.4404
GB
Female thread ISO228, 316L/1.4404
GE
Hose adapter ID=13mm, 316L/1.4404
GF
Hose adapter ID=16mm, 316L/1.4404
GH
Hose adapter ID=19mm, 316L/1.4404
GJ
Adhesive fitting tube 1/2", PVC
GK
Adhesive fitting 20x2mm tube, PVC
HA
Welding nipple EN10357, 1.4404/316L (DIN11850)
HB
Welding nipple ODT/SMS, 316L/1.4404
HC
Clamp ISO2852, 316L/1.4404
HD
Clamp DIN32676, 316L/1.4404
HE
Tri-Clamp, 316L/1.4404
HG
DIN11851, 316L/1.4404
HH
Aseptic DIN11864-1A, 316L/1.4404
HJ
Aseptic DIN11864-2A, 316L/1.4404
HK
SMS1145, 316L/1.4404
HL
ISO2853, 316L/1.4404
HN
Welding nipple ASME BPE, 1.4404/316L
HP
Welding nipple ISO2037, 1.4404/316L
Seal:
9
Special version, TSP-no. to be spec.
A
O-ring, EPDM
B
O-ring, Viton
C
O-ring, Kalrez
F
Aseptic shape, EPDM
G
Aseptic shape, Viton
H
Aseptic shape, Silicone
Additional Test, Certificate:
1
w/o
2
Mat. certificate (flange)
9
Special version, TSP-no. to be spec.
>Design:
CA
Process connection short
CB
Process connection short, RaDesign:
CA
Short
DK5HB-
Electromagnetic flowmeter H, distance disc
The set includes 2 distance discs incl.
screws and 2 seals.
For dimensions refer to the technical
documentation.
Nominal diameter:
1H
DN100 4"
80
DN80 3"
Process Connection:
99
Special version, TSP-no. to be spec.
HS
Distance disc
Seal:
9
Special version, TSP-no. to be spec.
F
Aseptic shape, EPDM
G
Aseptic shape, Silicone
DK5HM-
Wall-mount mounting kit DK5HM
Nominal Diameter:
15
DN15 1/2"
22
DN25 1"
26
DN25 DIN
H2
DN02 1/12"
H4
DN04 5/32"
H8
DN08 5/16"
DK5HW-
Welding kit DK5HW
Nominal Diameter:
15
DN02 - DN15 1/12" - 1/2"
1F
DN150 6"
1H
DN100 4"
1Z
DN125
22
DN25 1"
26
DN25 DIN
40
DN40 1-1/2"
50
DN50 2"
65
DN65 2-1/2"
80
DN80 3"
Material:
A
1.4301
DK5HA-
Adapter kit DK5HA
Replacement of sensor Promag A or
Promag H DN 25.
The set includes 2 adapters and 2 seals.
For dimensions refer to the technical
documentation.
Nominal Diameter:
15
DN 15 1/2"
22
DN 25 1"
26
DN 25 DIN
H2
DN 02 1/12"
H4
DN 04 5/32"
H8
DN 08 5/16"
Process Connection:
99
Special version, TSP-no. to be spec.
FA
DN15 PN40, 316L/1.4404, Promag A Flange EN1092-1 (DIN 2501)
FC
DN15 20K, 316L/1.4404, flange JIS B2220
HC
Clamp ISO2852, 316L/1.4404
HH
DIN11851, 316L/1.4404
HK
SMS1145, 316L/1.4404
HL
Welding nipple EN10357, 1.4404/316L (DIN11850)
HM
Welding nipple ODT/SMS, 316L/1.4404
Seal:
9
Special version, TSP-no. to be spec.
A
O-ring, EPDM
B
O-ring, Viton
C
O-ring, Kalrez
F
Aseptic shape, EPDM
G
Aseptic shape, Viton
H
Aseptic shape, Silicone
Additional Test:
1
w/o
9
Special version, TSP-no. to be spec.
DK5HR-
Grounding ring DK5HR
The grounding ring set includes
2 grounding rings
Nominal Diameter:
15
DN15 1/2"
22
DN25 1"
26
DN25 DIN
H8
DN2-DN8 1/12" - 5/16"
Material:
1
1.4435/316L, (Electrodes 316L/1.4435)
2
Alloy C-22, (Electrodes Alloy C-22)
5
Tantalum (Electrodes Tantalum)
Seal:
0
Not used
9
Special version, TSP-no. to be spec.
FXA193-
Communication interface FXA193
The service interface connects the
service port of Proline and ToF devices
with the serial interface RS 232C
(9 pin.) of a personal computer.
Contents of delivery:
- Serviceinterface with RS 232C
connection cable (9 pin.)
- FXA "USB" cable, the additional
power supply for FXA193 from USB-port
of the PC.
- Service Softw.ToF Tool-Fieldtool
Package
Approval:
9
Special version, TSP-no. to be spec.
A
For use in non-hazardous area
B
ATEX II (1) GD
C
CSA/FM Class I Div. 1
D
ATEX, CSA, FM
Connection Cable:
9
Special version, TSP-no. to be spec.
A
Proline device
B
ToF device
E
Proline and ToF device
F
Ex two-wire device
G
Proline device and Ex two-wire device
H
Proline, ToF and Ex two-wire device
X
Without connection cable