B 63-32 Chinese Manual Download

You can directly click the link below to download the PDF file of the B 63-32 Chinese manual. This manual covers the complete content including product overview, technical specifications, installation and commissioning, and troubleshooting.

B 63-32 Chinese manual PDF icon Download B 63-32 Chinese Manual.pdf

B 63-32 Product Overview

B 63-32 is an instrument device widely used in the field of industrial automation, typically for the measurement and control of parameters such as pressure, temperature, or flow. Its compact design and stable performance make it suitable for long-term operation in harsh industrial environments.

This manual is intended to help engineering technicians and procurement personnel fully understand the functional features, selection basis, and operating specifications of this model.

Main Technical Parameters

The following are the core technical indicators of the B 63-32, for reference in selection and system integration.

Parameter Item Typical Value/Range Remarks
Model B 63-32 Standard type
Measurement Range 0~32 MPa Customizable upon request
Accuracy Class 0.5% FS Full-scale error
Output Signal 4~20 mA / HART Two-wire
Power Supply 24 VDC Typical value
Process Connection M20×1.5 or 1/2 NPT Optional
Protection Rating IP65 Dustproof and waterproof
Operating Temperature -20~85 ℃ Ambient temperature

Installation Steps

Correct installation is the key to ensuring the measurement accuracy and long-term stability of the B 63-32. Please follow the steps below:

  1. Confirm that the installation location is free from strong vibration and corrosive gases, and is convenient for observation and maintenance.
  2. According to the process connection specifications, weld or thread the adapter fitting onto the pipeline or vessel.
  3. Use suitable sealing material (such as PTFE tape) to wrap the threads to avoid leakage.
  4. Screw the B 63-32 into the fitting and tighten it with a wrench. Never rotate the housing directly.
  5. Connect the electrical wiring, paying attention to power supply polarity and the grounding of the signal cable shielding layer.
  6. After power-on, check whether the output signal is normal, and perform zero calibration if necessary.

Operation and Calibration Points

Daily Operation

  • Regularly check whether the displayed value is consistent with the host computer; if the deviation is too large, troubleshoot.
  • Avoid over-range use; instantaneous pressure should not exceed 1.5 times the rated value.
  • Use a damp cloth to clean the housing; do not use corrosive solvents.

Zero and Span Calibration

  • Zero calibration: Under no pressure, adjust to 4 mA via a HART communicator or local keys.
  • Span calibration: Apply full-scale standard pressure and adjust to 20 mA.
  • The calibration cycle is recommended once every 12 months, or shortened according to working conditions.

Common Faults and Troubleshooting

Fault Phenomenon Possible Cause Handling Method
No output signal Power not connected, wiring error Check power supply and loop wiring
Output value too high/too low Zero drift, sensor damage Recalibrate or replace the sensor
Large display fluctuation Medium pulsation, poor grounding Add damping, improve shielding grounding
Communication failure Missing HART resistor, address conflict Check loop resistance and device address

Maintenance and Care Recommendations

To extend the service life of the B 63-32, it is recommended to perform an appearance and wiring inspection every 6 months and a comprehensive calibration every year. If used for corrosive media, the inspection cycle should be shortened.

When replacing spare parts, please use the original manufacturer's specified model to ensure measurement accuracy and explosion-proof performance (if applicable).

Selection and Procurement Considerations

  • Confirm the measurement medium, temperature, pressure range, and process connection specifications.
  • Select the output signal type (4~20 mA, HART, etc.) according to the control system requirements.
  • For explosive environments, choose intrinsically safe or flameproof types and verify the explosion-proof rating.
  • Request the B 63-32 Chinese manual and metrological verification certificate from the supplier.

For more technical information, please download the complete B 63-32 Chinese manual PDF file.