5p5b

Feature

Option

Parameter Description

Approval; Transmitter; Sensor:

AA

Non-hazardous area

BB

ATEX+IECEx; Z1/21,Ex de; Z1/21, IIC/IIIC

BD

ATEX+IECEx; Z1/21,Ex d; Z1/21, IIC/IIIC

BJ

ATEX+IECEx; Non-haz; Z1/21, IIC/IIIC

BL

ATEX+IECEx; Non-haz; Z2

BN

ATEX+IECEx; Z2; Z1/21, IIC/IIIC

BS

ATEX+IECEx; Z2; Z2, IIC

CD

CSA C/US; Cl.I,II,III Div.1, XP; Cl.I Cl.II,III Div.1, Gr.A-G

CN

CSA C/US; Cl.I Div.2, NI, Gr.A-D; Cl.I,II,III, Div.1, Gr.A-G

CS

CSA C/US; Cl.I Div.2,NI; Cl.I Div.2

CZ

CSA C/US; Z2; Z2, IIC

C2

CSA C/US; Z1/21,Ex de; Z1/21, IIC/IIIC

C4

CSA C/US; Z1/21,Ex d; Z1/21, IIC/IIIC

C6

CSA C/US; Z2; Z1/21, IIC/IIIC

GB

EAC; Z1/21, Ex de; Z1/21, IIC/IIIC

GD

EAC; Z1/21, Ex d; Z1/21, IIC/IIIC

GJ

EAC; Non-haz; Z1/21, IIC/IIIC

GL

EAC; Non-haz; Z2

GN

EAC; Z2; Z1/21, IIC/IIIC

GR

EAC; Non-hazardous area

GS

EAC; Z2; Z2, IIC

JD

JPN; Z1, Ex d; Z1, IIC

JJ

JPN; Non-haz; Z1, IIC

KD

KC Ex; Z1/21, Ex d; Z1/21, IIC/IIIC

MB

INMETRO; Z1/21,Ex de; Z1/21,IIC/IIIC

MD

INMETRO; Z1/21,Ex d; Z1/21, IIC/IIIC

MJ

INMETRO; Non-haz; Z1/21, IIC/IIIC

ML

INMETRO; Non-haz; Z2

MN

INMETRO; Z2; Z1/21, IIC/IIIC

MS

INMETRO; Z2; Z2, IIC

NB

NEPSI; Z1/21,Ex de; Z1/21,IIC/IIIC

ND

NEPSI; Z1/21,Ex d; Z1/21, IIC/IIIC

NJ

NEPSI; Non-haz; Z1/21, IIC/IIIC

NL

NEPSI; Non-haz; Z2

NN

NEPSI; Z2; Z1/21, IIC/IIIC

NS

NEPSI; Z2; Z2, IIC

UB

UK Ex; Z1/21,Ex de; Z1/21, IIC/IIIC

UD

UK Ex; Z1/21,Ex d; Z1/21, IIC/IIIC

UJ

UK Ex; Non-haz; Z1/21, IIC/IIIC

UL

UK Ex; Non-haz; Z2

UN

UK Ex; Z2; Z1/21, IIC/IIIC

UR

UK; Non-hazardous area

US

UK Ex; Z2; Z2, IIC

Power Supply:

D

DC 24V

E

AC 100...240V

I

AC 100...240V/DC 24V

X

Sensor only

9

Special version, please define TSP number

Output; Input 1:

BA

4-20mA HART

BB

***4-20mA + WirelessHART

CA

4-20mA HART Ex-i passive

CB

***4-20mA Ex-i + WirelessHART

CC

4-20mA HART Ex-i active

GA

PROFIBUS PA

HA

PROFIBUS PA Ex-i

LA

PROFIBUS DP

MA

Modbus RS485

MB

Modbus TCP over Ethernet-APL 10Mbit/s, SPE 10Mbit/s, Ethernet 100Mbit/s

MC

Modbus TCP over Ethernet-APL, Ex-i, 10Mbit/s

NA

EtherNet/IP, dual port

RA

PROFINET, dual port

RB

PROFINET over Ethernet-APL/SPE, 10Mbit/s

RC

PROFINET over Ethernet-APL, Ex-i, 10Mbit/s

SA

FOUNDATION Fieldbus

TA

FOUNDATION Fieldbus Ex-i

XX

Sensor only

99

Special version, please define TSP number

Output; Input 2:

A

None;

B

4-20mA

C

4-20mA Ex-i passive

D

Configurable I/O, default off

E

Pulse/frequency/switch output

F

Pulse output, phase shift

G

Pulse/frequency/switch output Ex-i passive

H

Relay

I

4-20mA input

J

Status input

K

*Pulse output Ex-i passive custody transfer

L

*Pulse output custody transfer

X

Sensor only

9

Special version, please define TSP number

Output; Input 3:

A

None;

B

4-20mA

C

4-20mA Ex-i passive

D

Configurable I/O, default off

E

Pulse/frequency/switch output

F

Pulse output, phase shift

G

Pulse/frequency/switch output Ex-i passive

H

Relay

I

4-20mA input

J

Status input

X

Sensor only

9

Special version, please define TSP number

Output; Input 4:

A

None;

B

4-20mA

C

4-20mA Ex-i passive

D

Configurable I/O, default off

E

Pulse/frequency/switch output

G

Pulse/frequency/switch output Ex-i passive

H

Relay

I

4-20mA input

J

Status input

X

Sensor only

9

Special version, please define TSP number

Display; Operation:

F

4-line backlit; optical keys

G

4-line backlit; optical keys + WLAN

X

Sensor only

9

Special version, please define TSP number

Integrated ISEM electronics module:

A

Sensor

B

Transmitter

9

Special version, please define TSP number

Transmitter housing:

A

Aluminum housing, with anti-corrosion coating

D

Polycarbonate

L

Cast stainless steel

X

Sensor only

9

Special version, please define TSP number

Sensor housing:

A

Aluminum housing, with anti-corrosion coating

L

Cast stainless steel

9

Special version, please define TSP number

Cable, sensor connection:

A

None

B

20m digital

D

***option not used D

E

..... m digital

F

..... ft digital

G

***option not used G

H

***option not used H

J

5m digital cable

L

10m digital cable

P

30m digital cable

1

5m signal cable

2

10m signal cable

3

20m signal cable

4

..... m remote signal cable

5

..... ft remote signal cable

6

..... ***m remote, armored

7

..... ***ft remote, armored

8

30m coil and signal cable

9

Special version, please define TSP number

Electrical connection:

A

Cable gland M20

B

Thread M20

C

Thread G1/2

D

Thread NPT1/2

L

Thread NPT1/2 + 1x plug connector M12x1

M

Cable gland M20 + 1x plug connector 7/8"

N

Cable gland M20 + 1x plug connector M12x1

P

Thread G1/2 + 1x plug connector M12x1

R

Cable gland M20 + 2x plug connector M12x1

S

Thread NPT1/2 + 2x plug connector M12x1

T

Thread G1/2 + 2x plug connector M12x1

U

Thread M20 + 1x plug connector M12x1

V

Thread M20 + 2x plug connector M12x1

1

Thread NPT1/2 + 1x plug M12x1 coding D

2

Cable gland M20 + 1x plug M12x1 coding D

3

Thread M20 + 1x plug connector 7/8"

4

Thread G1/2 + 1x plug connector 7/8"

5

Thread NPT1/2 + 1x plug connector 7/8"

6

JPN Ex d G1/2 thread

7

Thread G1/2 + 1x plug M12x1 coding D

8

Thread M20 + 1x plug M12x1 coding D

9

Special version, please define TSP number

Liner:

A

PFA

B

PFA high temperature

E

PTFE

F

ETFE

9

Special version, please define TSP number

Process connection:

A1K

Cl.150, carbon steel, flange ASME B16.5

A1S

Cl.150, stainless steel, flange ASME B16.5

A2K

Cl.300, carbon steel, flange ASME B16.5

A2S

Cl.300, stainless steel, flange ASME B16.5

A3K

Cl.600, carbon steel, flange ASME B16.5 ETFE

A3S

Cl.600, stainless steel, flange ASME B16.5 ETFE

A4K

Cl.900, carbon steel, flange ASME B16.5 ETFE

A4S

Cl.900, stainless steel, flange ASME B16.5 ETFE

D2K

PN10, carbon steel, flange EN1092-1

D2S

PN10, stainless steel, flange EN1092-1

D3K

PN16, carbon steel, flange EN1092-1

D3S

PN16, stainless steel, flange EN1092-1

D4K

PN25, carbon steel, flange EN1092-1

D4S

PN25, stainless steel, flange EN1092-1

D5K

PN40, carbon steel, flange EN1092-1

D5S

PN40, stainless steel, flange EN1092-1

N3K

10K, carbon steel, flange JIS B2220

N3S

10K, stainless steel, flange JIS B2220

N4K

20K, carbon steel, flange JIS B2220

N4S

20K, stainless steel, flange JIS B2220

999

Special version, please define TSP number

Electrode:

G

316L, bullet nose

H

Alloy C22, bullet nose

J

1.4435/316L, bullet nose 0 x DN upstream/downstream straight pipe

K

Alloy C22, bullet nose 0 x DN upstream/downstream straight pipe

L

1.4435/316L 0 x DN upstream/downstream straight pipe

M

Alloy C22 0 x DN upstream/downstream straight pipe

N

Tantalum 0 x DN upstream/downstream straight pipe

P

Platinum 0 x DN upstream/downstream straight pipe

Q

Titanium 0 x DN upstream/downstream straight pipe

0

316L

1

Alloy C22

2

Tantalum electrode

3

Platinum-iridium electrode (only 2 measuring electrodes)

4

Tantalum electrode (only 2 measuring electrodes)

5

Platinum-iridium electrode

6

***Duplex 1.4462

8

Titanium

9

Special version, please define TSP number

Calibration flow:

A

0.5%

B

0.2%

D

0.5%, 3-point, traceable ISO/IEC17025

E

0.2%, 3-point, traceable ISO/IEC17025

F

0.5% full range calibration

G

0.2% full range calibration

M

0.5%, 3-point

N

0.2%, 3-point

8

Special option, combined with water industry custody transfer standard (please select option 550)

9

Special version, please define TSP number

Device version:

A1

1

A2

2

>Operating language display:

AA

English

AB

German

AC

French

AD

Spanish

AE

Italian

AF

Dutch

AG

Portuguese

AH

Polish

AI

Russian

AJ

Turkish

AK

Simplified Chinese

AL

Japanese

AM

Korean

AN

***Arabic

AO

***Indonesian

AP

***Thai

AQ

***Vietnamese

AR

Czech

AT

Swedish

>>Sensor options:

CF

Severe environment

CG

Extended connection rod between transmitter and sensor, for insulation installation

CI

***option not used CI

CK

***option not used CK

CQ

IP68, Type 6P, potted

CS

Offshore version, Cl.150+300

CU

Offshore version, Cl.600+900

CV

Floating measurement

CW

Calibrated conductivity measurement

C9

Special version, please define TSP number

>>Factory parameter setting:

DA

Output 1

DB

Output 2

DG

***Totalizer

DH

Display; totalizer

DM

Output 3

DN

Output 4

D8

Set according to NAMUR NE 131

D9

Special version, please define TSP number

>>Application package:

EA

Extended HistoROM

EB

Heartbeat verification + monitoring

EC

ECC electrode cleaning

EL

OPC-UA server

E9

Special version, please define TSP number

>Custody transfer:

GM

*Liquid: water; MI-001

GN

***option not used GN

GO

*Liquid: water; OIML R49 Class 2

G9

Special version, please define TSP number

>>Service:

HC

*PWIS silicon removal (type A),

HD

*PWIS silicon removal (type B),

HE

PWIS silicon removal (type C),

HK

***option not used HK

HL

***option not used HL

HM

***option not used HM

I7

Paper documents

I8

***Product documents on CD

I9

Special version, please define TSP number

>>Test, certificate:

JA

3.1 Material certificate (measuring tube + flange) EN10204-3.1 inspection certificate

JB

Pressure test, internal pressure-bearing parts pressure inspection certificate

JL

***option not used JL

JN

Transmitter low temperature option: ambient temperature -50°C

KA

***EN10204-2.1 declaration of conformity

KB

***EN10204-2.2 test report

KK

ASME VIII Div.1 Appx. 8+4 (PT+RT), process connection, test report

KM

ASME VIII Div.1 Appx. 8 (PT), process connection, weld seam, test report

KP

ASME VIII Div.1 Appx. 8 + 4 (PT + RT), process connection (PT) + measuring tube (RT) weld seam, test report

K9

Special version, please define TSP number

>>Other approvals:

LA

SIL

LC

*PESR Cat. I/II/III

LD

CRN

LE

***option not used LE

LF

American Bureau of Shipping approval

LG

Lloyd's Register approval (UK classification society approval)

LH

Bureau Veritas approval

LI

***option not used LI

LJ

DNV approval

LK

PED Cat. I/II/III

LL

***option not used LL

LM

***option not used LM

LO

China Classification Society approval

LR

NACE MR0175 / ISO 15156 declaration (measuring tube, flange and electrode),

L1

KTW/W270 drinking water approval

L2

WRAS BS6920 drinking water approval

L3

ACS drinking water approval

L4

NSF 61 drinking water approval

L5

NSF 61 drinking water + hot water approval

L9

**Special version, please define TSP number

M1

TSG certificate/GC1

M2

TSG certificate/GC2

M9

Special version, please define TSP number

>>Installation accessories:

NB

Adapter RJ45 M12 (service interface)

N9

Special version, please define TSP number

>>Other accessories:

PA

Display protection

PB

Sunshade

PC

Pipe mounting kit

P8

Wireless antenna for extended range

P9

Special version, please define TSP number

>Firmware version:

58

01.06.zz, Modbus RS485, DevRev07

60

01.06.zz, HART, DevRev07

61

01.00.zz, PROFINET o. Ethernet-APL/SPE, 10Mbit/s DevRev01

62

01.00.zz, Modbus TCP o.Ethernet-APL/SPE, 10Mbit/s DevRev01

63

01.05.zz, Modbus RS485, DevRev06

64

01.05.zz, HART, DevRev06

65

01.01.zz, PROFINET

66

01.01.zz, PROFIBUS PA

67

***01.01.zz, Modbus RS485, DevRev01

68

***01.01.zz, HART, DevRev01

70

01.00.zz, PROFIBUS PA

71

01.00.zz, PROFINET

72

01.00.zz, FOUNDATION Fieldbus

73

01.00.zz, EtherNet/IP

74

***01.00.zz, Modbus RS485

75

01.00.zz, PROFIBUS DP, DevRev01

76

***01.00.zz, HART, DevRev01

>>Marking:

Z1

Tag (TAG), see additional notes

Z2

Bus address, see additional notes