5p5b
Feature
Option
Parameter Description
Approval; Transmitter; Sensor:
AA
Non-hazardous area
BB
ATEX+IECEx; Z1/21,Ex de; Z1/21, IIC/IIIC
BD
ATEX+IECEx; Z1/21,Ex d; Z1/21, IIC/IIIC
BJ
ATEX+IECEx; Non-haz; Z1/21, IIC/IIIC
BL
ATEX+IECEx; Non-haz; Z2
BN
ATEX+IECEx; Z2; Z1/21, IIC/IIIC
BS
ATEX+IECEx; Z2; Z2, IIC
CD
CSA C/US; Cl.I,II,III Div.1, XP; Cl.I Cl.II,III Div.1, Gr.A-G
CN
CSA C/US; Cl.I Div.2, NI, Gr.A-D; Cl.I,II,III, Div.1, Gr.A-G
CS
CSA C/US; Cl.I Div.2,NI; Cl.I Div.2
CZ
CSA C/US; Z2; Z2, IIC
C2
CSA C/US; Z1/21,Ex de; Z1/21, IIC/IIIC
C4
CSA C/US; Z1/21,Ex d; Z1/21, IIC/IIIC
C6
CSA C/US; Z2; Z1/21, IIC/IIIC
GB
EAC; Z1/21, Ex de; Z1/21, IIC/IIIC
GD
EAC; Z1/21, Ex d; Z1/21, IIC/IIIC
GJ
EAC; Non-haz; Z1/21, IIC/IIIC
GL
EAC; Non-haz; Z2
GN
EAC; Z2; Z1/21, IIC/IIIC
GR
EAC; Non-hazardous area
GS
EAC; Z2; Z2, IIC
JD
JPN; Z1, Ex d; Z1, IIC
JJ
JPN; Non-haz; Z1, IIC
KD
KC Ex; Z1/21, Ex d; Z1/21, IIC/IIIC
MB
INMETRO; Z1/21,Ex de; Z1/21,IIC/IIIC
MD
INMETRO; Z1/21,Ex d; Z1/21, IIC/IIIC
MJ
INMETRO; Non-haz; Z1/21, IIC/IIIC
ML
INMETRO; Non-haz; Z2
MN
INMETRO; Z2; Z1/21, IIC/IIIC
MS
INMETRO; Z2; Z2, IIC
NB
NEPSI; Z1/21,Ex de; Z1/21,IIC/IIIC
ND
NEPSI; Z1/21,Ex d; Z1/21, IIC/IIIC
NJ
NEPSI; Non-haz; Z1/21, IIC/IIIC
NL
NEPSI; Non-haz; Z2
NN
NEPSI; Z2; Z1/21, IIC/IIIC
NS
NEPSI; Z2; Z2, IIC
UB
UK Ex; Z1/21,Ex de; Z1/21, IIC/IIIC
UD
UK Ex; Z1/21,Ex d; Z1/21, IIC/IIIC
UJ
UK Ex; Non-haz; Z1/21, IIC/IIIC
UL
UK Ex; Non-haz; Z2
UN
UK Ex; Z2; Z1/21, IIC/IIIC
UR
UK; Non-hazardous area
US
UK Ex; Z2; Z2, IIC
Power Supply:
D
DC 24V
E
AC 100...240V
I
AC 100...240V/DC 24V
X
Sensor only
9
Special version, please define TSP number
Output; Input 1:
BA
4-20mA HART
BB
***4-20mA + WirelessHART
CA
4-20mA HART Ex-i passive
CB
***4-20mA Ex-i + WirelessHART
CC
4-20mA HART Ex-i active
GA
PROFIBUS PA
HA
PROFIBUS PA Ex-i
LA
PROFIBUS DP
MA
Modbus RS485
MB
Modbus TCP over Ethernet-APL 10Mbit/s, SPE 10Mbit/s, Ethernet 100Mbit/s
MC
Modbus TCP over Ethernet-APL, Ex-i, 10Mbit/s
NA
EtherNet/IP, dual port
RA
PROFINET, dual port
RB
PROFINET over Ethernet-APL/SPE, 10Mbit/s
RC
PROFINET over Ethernet-APL, Ex-i, 10Mbit/s
SA
FOUNDATION Fieldbus
TA
FOUNDATION Fieldbus Ex-i
XX
Sensor only
99
Special version, please define TSP number
Output; Input 2:
A
None;
B
4-20mA
C
4-20mA Ex-i passive
D
Configurable I/O, default off
E
Pulse/frequency/switch output
F
Pulse output, phase shift
G
Pulse/frequency/switch output Ex-i passive
H
Relay
I
4-20mA input
J
Status input
K
*Pulse output Ex-i passive custody transfer
L
*Pulse output custody transfer
X
Sensor only
9
Special version, please define TSP number
Output; Input 3:
A
None;
B
4-20mA
C
4-20mA Ex-i passive
D
Configurable I/O, default off
E
Pulse/frequency/switch output
F
Pulse output, phase shift
G
Pulse/frequency/switch output Ex-i passive
H
Relay
I
4-20mA input
J
Status input
X
Sensor only
9
Special version, please define TSP number
Output; Input 4:
A
None;
B
4-20mA
C
4-20mA Ex-i passive
D
Configurable I/O, default off
E
Pulse/frequency/switch output
G
Pulse/frequency/switch output Ex-i passive
H
Relay
I
4-20mA input
J
Status input
X
Sensor only
9
Special version, please define TSP number
Display; Operation:
F
4-line backlit; optical keys
G
4-line backlit; optical keys + WLAN
X
Sensor only
9
Special version, please define TSP number
Integrated ISEM electronics module:
A
Sensor
B
Transmitter
9
Special version, please define TSP number
Transmitter housing:
A
Aluminum housing, with anti-corrosion coating
D
Polycarbonate
L
Cast stainless steel
X
Sensor only
9
Special version, please define TSP number
Sensor housing:
A
Aluminum housing, with anti-corrosion coating
L
Cast stainless steel
9
Special version, please define TSP number
Cable, sensor connection:
A
None
B
20m digital
D
***option not used D
E
..... m digital
F
..... ft digital
G
***option not used G
H
***option not used H
J
5m digital cable
L
10m digital cable
P
30m digital cable
1
5m signal cable
2
10m signal cable
3
20m signal cable
4
..... m remote signal cable
5
..... ft remote signal cable
6
..... ***m remote, armored
7
..... ***ft remote, armored
8
30m coil and signal cable
9
Special version, please define TSP number
Electrical connection:
A
Cable gland M20
B
Thread M20
C
Thread G1/2
D
Thread NPT1/2
L
Thread NPT1/2 + 1x plug connector M12x1
M
Cable gland M20 + 1x plug connector 7/8"
N
Cable gland M20 + 1x plug connector M12x1
P
Thread G1/2 + 1x plug connector M12x1
R
Cable gland M20 + 2x plug connector M12x1
S
Thread NPT1/2 + 2x plug connector M12x1
T
Thread G1/2 + 2x plug connector M12x1
U
Thread M20 + 1x plug connector M12x1
V
Thread M20 + 2x plug connector M12x1
1
Thread NPT1/2 + 1x plug M12x1 coding D
2
Cable gland M20 + 1x plug M12x1 coding D
3
Thread M20 + 1x plug connector 7/8"
4
Thread G1/2 + 1x plug connector 7/8"
5
Thread NPT1/2 + 1x plug connector 7/8"
6
JPN Ex d G1/2 thread
7
Thread G1/2 + 1x plug M12x1 coding D
8
Thread M20 + 1x plug M12x1 coding D
9
Special version, please define TSP number
Liner:
A
PFA
B
PFA high temperature
E
PTFE
F
ETFE
9
Special version, please define TSP number
Process connection:
A1K
Cl.150, carbon steel, flange ASME B16.5
A1S
Cl.150, stainless steel, flange ASME B16.5
A2K
Cl.300, carbon steel, flange ASME B16.5
A2S
Cl.300, stainless steel, flange ASME B16.5
A3K
Cl.600, carbon steel, flange ASME B16.5 ETFE
A3S
Cl.600, stainless steel, flange ASME B16.5 ETFE
A4K
Cl.900, carbon steel, flange ASME B16.5 ETFE
A4S
Cl.900, stainless steel, flange ASME B16.5 ETFE
D2K
PN10, carbon steel, flange EN1092-1
D2S
PN10, stainless steel, flange EN1092-1
D3K
PN16, carbon steel, flange EN1092-1
D3S
PN16, stainless steel, flange EN1092-1
D4K
PN25, carbon steel, flange EN1092-1
D4S
PN25, stainless steel, flange EN1092-1
D5K
PN40, carbon steel, flange EN1092-1
D5S
PN40, stainless steel, flange EN1092-1
N3K
10K, carbon steel, flange JIS B2220
N3S
10K, stainless steel, flange JIS B2220
N4K
20K, carbon steel, flange JIS B2220
N4S
20K, stainless steel, flange JIS B2220
999
Special version, please define TSP number
Electrode:
G
316L, bullet nose
H
Alloy C22, bullet nose
J
1.4435/316L, bullet nose 0 x DN upstream/downstream straight pipe
K
Alloy C22, bullet nose 0 x DN upstream/downstream straight pipe
L
1.4435/316L 0 x DN upstream/downstream straight pipe
M
Alloy C22 0 x DN upstream/downstream straight pipe
N
Tantalum 0 x DN upstream/downstream straight pipe
P
Platinum 0 x DN upstream/downstream straight pipe
Q
Titanium 0 x DN upstream/downstream straight pipe
0
316L
1
Alloy C22
2
Tantalum electrode
3
Platinum-iridium electrode (only 2 measuring electrodes)
4
Tantalum electrode (only 2 measuring electrodes)
5
Platinum-iridium electrode
6
***Duplex 1.4462
8
Titanium
9
Special version, please define TSP number
Calibration flow:
A
0.5%
B
0.2%
D
0.5%, 3-point, traceable ISO/IEC17025
E
0.2%, 3-point, traceable ISO/IEC17025
F
0.5% full range calibration
G
0.2% full range calibration
M
0.5%, 3-point
N
0.2%, 3-point
8
Special option, combined with water industry custody transfer standard (please select option 550)
9
Special version, please define TSP number
Device version:
A1
1
A2
2
>Operating language display:
AA
English
AB
German
AC
French
AD
Spanish
AE
Italian
AF
Dutch
AG
Portuguese
AH
Polish
AI
Russian
AJ
Turkish
AK
Simplified Chinese
AL
Japanese
AM
Korean
AN
***Arabic
AO
***Indonesian
AP
***Thai
AQ
***Vietnamese
AR
Czech
AT
Swedish
>>Sensor options:
CF
Severe environment
CG
Extended connection rod between transmitter and sensor, for insulation installation
CI
***option not used CI
CK
***option not used CK
CQ
IP68, Type 6P, potted
CS
Offshore version, Cl.150+300
CU
Offshore version, Cl.600+900
CV
Floating measurement
CW
Calibrated conductivity measurement
C9
Special version, please define TSP number
>>Factory parameter setting:
DA
Output 1
DB
Output 2
DG
***Totalizer
DH
Display; totalizer
DM
Output 3
DN
Output 4
D8
Set according to NAMUR NE 131
D9
Special version, please define TSP number
>>Application package:
EA
Extended HistoROM
EB
Heartbeat verification + monitoring
EC
ECC electrode cleaning
EL
OPC-UA server
E9
Special version, please define TSP number
>Custody transfer:
GM
*Liquid: water; MI-001
GN
***option not used GN
GO
*Liquid: water; OIML R49 Class 2
G9
Special version, please define TSP number
>>Service:
HC
*PWIS silicon removal (type A),
HD
*PWIS silicon removal (type B),
HE
PWIS silicon removal (type C),
HK
***option not used HK
HL
***option not used HL
HM
***option not used HM
I7
Paper documents
I8
***Product documents on CD
I9
Special version, please define TSP number
>>Test, certificate:
JA
3.1 Material certificate (measuring tube + flange) EN10204-3.1 inspection certificate
JB
Pressure test, internal pressure-bearing parts pressure inspection certificate
JL
***option not used JL
JN
Transmitter low temperature option: ambient temperature -50°C
KA
***EN10204-2.1 declaration of conformity
KB
***EN10204-2.2 test report
KK
ASME VIII Div.1 Appx. 8+4 (PT+RT), process connection, test report
KM
ASME VIII Div.1 Appx. 8 (PT), process connection, weld seam, test report
KP
ASME VIII Div.1 Appx. 8 + 4 (PT + RT), process connection (PT) + measuring tube (RT) weld seam, test report
K9
Special version, please define TSP number
>>Other approvals:
LA
SIL
LC
*PESR Cat. I/II/III
LD
CRN
LE
***option not used LE
LF
American Bureau of Shipping approval
LG
Lloyd's Register approval (UK classification society approval)
LH
Bureau Veritas approval
LI
***option not used LI
LJ
DNV approval
LK
PED Cat. I/II/III
LL
***option not used LL
LM
***option not used LM
LO
China Classification Society approval
LR
NACE MR0175 / ISO 15156 declaration (measuring tube, flange and electrode),
L1
KTW/W270 drinking water approval
L2
WRAS BS6920 drinking water approval
L3
ACS drinking water approval
L4
NSF 61 drinking water approval
L5
NSF 61 drinking water + hot water approval
L9
**Special version, please define TSP number
M1
TSG certificate/GC1
M2
TSG certificate/GC2
M9
Special version, please define TSP number
>>Installation accessories:
NB
Adapter RJ45 M12 (service interface)
N9
Special version, please define TSP number
>>Other accessories:
PA
Display protection
PB
Sunshade
PC
Pipe mounting kit
P8
Wireless antenna for extended range
P9
Special version, please define TSP number
>Firmware version:
58
01.06.zz, Modbus RS485, DevRev07
60
01.06.zz, HART, DevRev07
61
01.00.zz, PROFINET o. Ethernet-APL/SPE, 10Mbit/s DevRev01
62
01.00.zz, Modbus TCP o.Ethernet-APL/SPE, 10Mbit/s DevRev01
63
01.05.zz, Modbus RS485, DevRev06
64
01.05.zz, HART, DevRev06
65
01.01.zz, PROFINET
66
01.01.zz, PROFIBUS PA
67
***01.01.zz, Modbus RS485, DevRev01
68
***01.01.zz, HART, DevRev01
70
01.00.zz, PROFIBUS PA
71
01.00.zz, PROFINET
72
01.00.zz, FOUNDATION Fieldbus
73
01.00.zz, EtherNet/IP
74
***01.00.zz, Modbus RS485
75
01.00.zz, PROFIBUS DP, DevRev01
76
***01.00.zz, HART, DevRev01
>>Marking:
Z1
Tag (TAG), see additional notes
Z2
Bus address, see additional notes