超声波流量计
Technical Data
CompareLiquids
| Measuring Principle | |
| Product headline | std_productprofile_product_usp_60153_1581515154. std_productprofile_product_field_of_application_60154_1581515575. |
| Sensor features | std_productprofile_product_benefits_60155_1581515575. std_productprofile_product_benefits_60156_1581515575. std_productprofile_product_benefits_60157_1581515575. std_successorproducts_product_differentiating_tech_features_60158_1581515675. std_successorproducts_product_differentiating_tech_features_60159_1581515675. std_successorproducts_product_differentiating_tech_features_60160_1581515675. |
| Transmitter features | std_productprofile_product_benefits_60161_1581516129. std_productprofile_product_benefits_60162_1581516129. std_productprofile_product_benefits_60163_1581516129. std_successorproducts_product_differentiating_tech_features_60164_1581516129. std_successorproducts_product_differentiating_tech_features_60165_1581516129. std_successorproducts_product_differentiating_tech_features_60166_1581516129. |
| Nominal diameter range | DN 300 to 1200(12" to 48") |
| Wetted materials | Sensor housing: 1.4404/DN 17440 (316L/AISI) Weld-in parts: 1.4404/DN 17440 (316L/AISI) Measuring pipe: ST 37.2 (carbon steel) |
| Measured variables | Volume flow channel 1 or 2, sound velocity, flow velocity, average volume flow, average sound velocity, average flow velocity, totalizer |
| Max. measurement error | +/-0.5 % |
| Measuring range | 0 to 40000 m3/h 0 to 180000GPM |
| Max. process pressure | PN 16, Cl. 150 |
| Medium temperature range | -20 to +60°C (-4 to 140°F) |
| Ambient temperature range | Transmitter: –20 to +60 °C (–4 to +140 °F) Sensor: –20 to +80 °C (–4 to +176 °F) |
| Transmitter housing material | Wall-mounted housing: powder-coated die-cast aluminum |
| Degree of protection | Transmitter IP 67 (NEMA 4X) Sensor IP 68 (NEMA 6P) |
| Display/Operation | 4 lines backlit display with three optical keys |
| Outputs | 1x 4-20 mA HART 1x Pulse/frequency/switch output (passive) |
| Inputs | N/A |
| Digital communication | HART, PROFIBUS PA, PROFIBUS DP, FOUNDATION Fieldbus |
| Power supply | AC 85 to 260 V AC 20 to 55 V DC 16 to 62V |
| Hazardous area approvals | FM CSA |
| Product safety | CE, C-Tick |
The Prosonic Flow 93C inline flowmeter is designed specifically for water and wastewater flow measurement. The complete system consists of a wall-mounted Prosonic Flow 93 transmitter and an optimally designed Prosonic Flow W insertion sensor. With the Prosonic Flow 93C inline flowmeter, customers benefit from the high accuracy unique to ultrasonic flow measurement systems and from traceable instrument calibration.
Advantages
No production losses - the production process does not need to be interrupted when removing or replacing sensor parts
No pressure loss - full-bore design
High process transparency - diagnostic functions
Optimum performance - extended functions and diagnostic software
Flexible data transmission - a choice of communication methods
Automatic data recovery for service purposes
Application areas
Choice of measuring principle not limited by pressure, density, temperature, conductivity and viscosity
Inline measurement of process water, brine, demineralized water, drinking water and wastewater flow
Instrument features:
International drinking water measurement approval
Nominal diameter: DN 300 ~ 2000 (12~ 80")
Medium temperature: –10 ~ 80 °C (14~ 176 °F)
Aluminum transmitter housing
Four-line backlit display with touch control
HART, PROFIBUS PA/DP, FOUNDATION Fieldbus
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Ultrasonic Flow Meter Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Ultrasonic Flow Meter Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Ultrasonic Flow Meter Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Ultrasonic Flow Meter Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Ultrasonic Flow Meter.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Ultrasonic Flow Meter for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserProsonic Flow 93T portable
Endress+HauserProsonic Flow 91WA1 Clamp On 1Ch/1Set
Endress+Hauser超声波浓度计 D9FB
Endress+Hauser超声波流量计 93W
Endress+Hauser超声波流量计 9B2B
Endress+Hauser超声波浓度计 D9IB
Endress+Hauser超声波流量计
Endress+Hauser