Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TC12 热电偶温度计

TC12 热电偶温度计

Thermocouple TC12

Configurable Models 1 models
The high modular and robust thermometer finds its use in several applications in almost all industries. An optional head transmitter, with all common communication protocols, makes the device ready to use with enhanced measurement accuracy and reliability compared to directly wired sensors. A variety of process connections, dimensions and materials offer flexible application possibilities.
Compare

Thermometer

Measuring Principle
Characteristic / Application metric style
modular temperature assembly
universal range of application
suitable for hazardous areas
process connection as compression fitting
without neck
incl. thermowell / protection tube (metal)
Thermowell / protection tube welded protection tube
Insert / probe mineral insulated (MI), flexible
Outer diameter protection tube / Insert 9,0 mm (0,35'')
11,0 mm (0,43'')
12,0 mm (0,47'')
Max. immersion length on request up to 10.000,00 mm (393,70'')
Material protection tube/ thermowell 1.4404 (316L)
1.4571 (316Ti)
Alloy 600 (2.4816)
Alloy C276 (2.4819)
Optional coating Not defined
Process connection compression fitting:
G1/2"
G1"
R1/2"
R3/4"
Tip shape straight
reduced
tapered
Surface roughness Ra 0,8 μm (31,5 μin.)
Operating temperature range Type K:
max. 1.100 °C
(max. 2.012 °F)
Type J:
max. 800 °C
(max. 1.472 °F)
Max. process pressure (static) at 20 °C: 40 bar (580 psi)
Accuracy class 1 acc. to IEC 60584
Response time depending on configuration
t50 = 6 s
t90 = 13 s
Integration head transmitter yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
Ex - approvals ATEX II
ATEX IECEx
NEPSI
IECEx
EAC Ex
Certification Gost Metrology
SIL (transmitter only)

Flexibly configurable, robust thermometer suitable for applications in almost all industries. Devices with an optional head-mounted transmitter are compatible with all common communication protocols, are ready for immediate use and offer higher measuring accuracy and reliability than directly wired sensors. A wide range of process connections, versions and materials provides flexibility in use.

 

Benefits

Modular design with a standard terminal head conforming to DIN EN 50446 and customer-specific immersion length for high flexibility

Highly compatible measuring element, designed in accordance with DIN 43772

Short tapered/tapered tip for faster response time

Types of protection for use in hazardous areas: intrinsically safe (Ex ia), non-sparking (Ex nA)

Easy selection of the head transmitter: analog output 4 to 20 mA, HART®, PROFIBUS® PA or FF fieldbus

 

 

E+H Product Configurator

Please enter the product model to configure

Product Comparison

Please enter the product models to compare in the fields below. Up to three products can be compared

 

   

Technical Documentation

   

Technical Specifications

 

 

Documents/Manuals/Software

 

 

Accessories/Spare Parts

 

Source:Endress+Hauserwebsite public information

Model Name
TC12-AAH1MMMA1000 热电偶温度计
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Thermocouple Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Thermocouple Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Thermocouple Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Thermocouple Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Thermocouple.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.