Thermocouple TC61
Technical Data
CompareThermometer
| Measuring Principle | |
| Characteristic / Application | metric style modular temperature assembly for heavy duty applications suitable for hazardous areas with neck incl. thermowell / protection tube (metal) |
| Thermowell / protection tube | welded protection tube |
| Insert / probe | mineral insulated (MI), flexible |
| Outer diameter protection tube / Insert | 9,0 mm (0,35'') 11,0 mm (0,43'') 12,0 mm (0,47'') |
| Max. immersion length on request | up to 10.000,00 mm (393,70'') |
| Material protection tube/ thermowell | 1.4404 (316L) 1.4571 (316Ti) Alloy 600 (2.4816) Alloy C276 (2.4819) |
| Optional coating | Not defined |
| Process connection | male thread: G1/2" G3/4" G1" NPT1/2" NPT3/4" M20x1,5 compression fitting: G1/2" G1" flange: DN25 PN40 B1 (EN1092) DN40 PN40 B1(EN1092) DN50 PN40 B1 (EN1092) ASME 1" 150 RF (B16.5) ASME 1" 300 RF (B16.5) |
| Tip shape | straight reduced tapered |
| Surface roughness Ra | 0,8 μm (31,5 μin.) |
| Operating temperature range | Type K: -40 °C ...1.100 °C (-40 °F ...2.012 °F) Type J: -40 °C ...750 °C (-40 °F ...1.382 °F) |
| Max. process pressure (static) | at 20 °C: 100 bar (1.450 psi) |
| Accuracy | class 1 acc. to IEC 60584 |
| Response time | depending on configuration t50 = 3 s t90 = 7 s |
| Integration head transmitter | yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS) |
| Ex - approvals | ATEX IECEx NEPSI EAC Explosion proof |
| Certification | Gost Metrology SIL (transmitter only) |
This thermocouple thermometer is robust and suitable for harsh operating conditions and safety-critical measuring applications in the chemical, oil, gas and energy industries. The robust protection tube and special materials are sufficient to cope with harsh operating environments, corrosive substances and high pressure. The optional transmitter is compatible with various common communication protocols and can be installed and used immediately, improving measuring accuracy and reliability compared to directly wired sensors, with flexible equipment configuration.
Advantages
Explosion protection types: intrinsically safe (Ex ia), flameproof (Ex d), non-sparking (Ex nA)
High measuring insert compatibility, designed in accordance with DIN 43772
Extension neck prevents the transmitter from overheating
Short-taper/conical tip for a faster response time
Modular design with a standard terminal head in accordance with DIN EN 50446 and customer-specified immersion length for high flexibility
Application areas
Heavy-duty machinery applications
Oil and gas industry
Measuring range: –40 ... 1 100 °C (–40 ... 2 012 °F)
Static pressure up to 75 bar depending on the process connection used
Degree of protection: IP68
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Thermocouple Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Thermocouple.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Thermocouple Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Thermocouple.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Thermocouple Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Thermocouple.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Thermocouple Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Thermocouple.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Thermocouple for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.