Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

TT511 棒材保护套管

TT511 棒材保护套管

Vanstone Thermowell TT511

It is a specially designed thermowell for thermometer installation. The thermowell shaft and the process connection flange are not interconnected. For installation, the collar of the thermowell is fitted between two flanges; on the one hand it is fitted onto the thermowell and on the other hand it is bolted to the connection nozzle on the process side. Many different flange versions are available to secure the unit to the permanently installed nozzle flange. It is machined from solid bar stock.
Compare

Thermowell

Measuring Principle Bar stock Thermowell
Characteristic / Application metric style
Vanstone type
with collar flange
Head connection thread:
1/2" NPT
without connection
Maximum standard immersion length 500 mm (19,69")
Max. immersion length on request 500 mm (19,69")
Process connection Collar flange
1 1/2" 150
1 1/2" 300
1 1/2" 400
1 1/2" 600
1 1/2" 900
1 1/2" 1500
2" 150
2" 300
2" 400
2" 600
2" 900
2" 1500
2" 2500
DN25 PN40
DN25 PN100
DN50 PN40
DN50 PN63
DN50 PN100
DN80 PN40
Thermowell root diameter 30 mm (1,18")
20 mm (0,79")
Medium contact material 1.4401 (316)
1.4571 (316Ti)
Alloy400
Alloy625
A182 F51
A182 F55
Wetted part finishing (Ra) <= 1,6 µm (63.00µin)
<= 0,8 µm (31.50 µin) or roughened to Ra=6 (0.24µm)
Tip shape conical or tapered
Temperature range -200…700°C (-328…1.292 °F)
Max. process pressure (static) depending on process connection up to 2500 lbs
Max. process pressure at 400 °C depends on process connection

TT511 bar stock thermowell, Vanstone-type metric thermowell designed for the oil and gas industry

Advantages

  • Solid thermowell made from drilled bar stock.

  • The standard product meets the specific requirements of various industries. The insertion depth and the thermowell structure can be flexibly selected according to the process parameters.

  • Complies with Shell specifications: S.38.113 (revision D) and S.38.114 (revision D)

  • Precise thermowell calculation ensures safe plant production.

  • The Vanstone design significantly reduces costs:

    After replacing the thermowell, the flange can be reused, allowing flexible selection of the flange material and reducing spare parts and warehousing requirements.

Field of application

Thermowell specially designed for thermometer installation. The thermowell stem and the process connection flange are not connected. During installation, the thermowell flange is placed between two flanges; on the one hand it fixes the thermowell, and on the other hand it bolts the connection nozzle to the process side. Various types of flanges are available to permanently fix the device to the installed nozzle flange. Machined from solid bar stock.

The thermowell can be used in industries with high process requirements. It is mainly used in the oil and gas and petrochemical industries. The process connection flange is not welded to the base of the thermowell but is designed as a Vanstone flange. The special Vanstone thermowell design enables a wide range of applications and is suitable for RTD and thermocouple thermometers.

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

Technical documentation

   

Technical data

 

 

   

Documents/Manuals/Software

 

 

   

Accessories/Spare parts

 

 

Source:Endress+Hauserpublic information from the website

Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Temperature Sleeve Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Temperature Sleeve Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Temperature Sleeve Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Temperature Sleeve Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Temperature Sleeve.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Temperature Sleeve for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.