FMI51 E+H电容液位计

Liquicap M FMI51

Configurable Models 11 models
Liquicap FMI51 is a reliable fully insulated rod probe for continuous level monitoring in liquids, particularly in build-up forming media and extremely high temperatures. The measurement is independent of the dielectric constant (dc). Used in conjunction with Fieldgate FXA320 (remote measured value interrogation using Internet technology), Liquicap is an ideal solution for Inventory Management Solutions.
Compare

Continuous / Liquids

Measuring Principle Capacitive
Characteristic / Application Fully insulated rod probe, for standart- and extreme process conditions (temperature, pressure, build-up)
Interface measurement Interfaces liquid / liquid also with emulsion layers
Specialities Inactive length
Factory calibrated
short response time by change of value
Supply / Communication 12-36V DC HART
PFM
Accuracy Repeatablity 0,1%
Linearity error for conductive liquids <0.5%
Ambient temperature -50°C...+70°C
-58°F...+158°F
Process temperature -80°C...200°C
-112°F...392°F
Process pressure / max. overpressure limit Vacuum ... 100 bar
(Vaccum ... 1450 psi)
Main wetted parts Insulation material: PTFE,PFA
316L
Process connection G1/2, G 3/4, G 1, G1 1/2 /NPT 1/2, NPT 3/4, NPT 1", NPT1 1/2
Flanges from DN25.../ASME 1".../JIS...
Process connection hygienic Tri-Clamp ISO02852 gap free plated
Dairy coupling
Flush-mounted seal
Sensor length Total length: 6m (20ft)
Inactive length: max. 2m (7ft)
Max. measurement distance 0.1 m ... 4.0 m
(0.3 ft ... 13 ft)
Communication 4...20mA HART
PFM
Certificates / Approvals ATEX, FM, CSA, IEC Ex, TIIS, INMETRO, NEPSI, EAC
Safety approvals SIL
Design approvals EN 10204-3.1
NACE MR0175
Hygienic approvals 3A, EHEDG
Marine approval GL/ ABS/ DNV
Options Separate housing
gas-tight probe seal
Application limits Insufficient clearance towards ceiling
Changing, non-conductive
media, conductivity
< 100 μS/cm
Notice the pressure and temperature derating

The FMI51 is the rod version. If a cable capacitive level transmitter is required, use the FMI52. For measuring light solids, use the FTC260.

The Liquicap FMI51/FM151 is a fully insulated rod probe for level monitoring in a wide range of liquids, and it also measures effectively in media prone to buildup and at extremely high temperatures. The measurement is unaffected by the dielectric constant (DC). Used together with the Fieldgate FXA320 (remote reading of measured values via Internet technology), Liquicap is the ideal choice for inventory management solutions.

Benefits:

  • Compliant with IEC 61508, can be used in safety systems up to functional safety level SIL2

  • Numerous certificates and approvals for reliable use and a wide range of applications

  • No calibration required (factory preset). No calibration is needed when measuring media with a conductivity of 100 μS/cm and higher

  • Process wetted parts made of corrosion-resistant, FDA-approved materials

  • Menu-guided on-site configuration via plain text display (optional)

  • Two-stage overvoltage protection

Application areas:

The instrument is unaffected by the dielectric constant (DC); liquids have a conductivity of 100 μS/cm, and multiple liquids can be measured without recalibration.

  • Process connection: flange and thread

  • Process pressure: -1...+100 bar (+1,450 psi)

  • Measuring range: 0.1...4.0 m (0.3...13 ft)

  • Temperature: -80...+200 °C (-112...+392 °F)

  • International explosion protection approval, WHG overflow protection, SIL, hygienic approval, marine approval

 

 

E+H product model configurator

Please enter the product model to configure

Product comparison

Please enter the product models to be compared in the input boxes below; up to three products can be compared

 

   

Technical information

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

   

Measuring principle video

Source: public information from the Endress+Hauser website

Model Name
FMI51-A1ATCJB2A1A 电容液位计
FMI51-A1AGCJB2A2A 电容液位计
FMI51-H1BGEJA3A1A 电容液位计
FMI51-A2AGDJB2A1A 电容液位计
FMI51-A2AGDJA2A1A 电容液位计
FMI51-A1BTDJA1A1A 电容液位计
FMI51-A1AGDJA3A1F 电容液位计
FMI51-A1BTDJB3A1A 电容液位计
FMI51-A1BAFJB2A1A 电容液位计
FMI51-A1AGDJA2A1A 电容液位计
FMI51-A1AGDJB3A1A 电容液位计
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Capacitance Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Capacitance.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Capacitance Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Capacitance.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Capacitance Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Capacitance.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Capacitance Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Capacitance.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.