Nivector FTI26
Technical Data
ComparePoint Level / Solids
| Measuring Principle | Capacitive Solid |
| Characteristic / Application | Compact for all types of powdered solids / small-grain bulk solids |
| Specialities | Active build-up compensation |
| Supply / Communication | 12 V...30 VDC |
| Ambient temperature | -20°C...+60°C (-4°F...+140°F) |
| Process temperature | -20°C...+80°C (-4°F...+176°F) |
| Main wetted parts | PC, ECTFE "Protector" FDA listed material PBT-GF (according to 21 CFR 177.1660) |
| Process connection | G1 |
| Communication | 12 V...30 VDC IO-Link |
| Safety approvals | ATEX, CSA C/US, IEC Ex, EAC Ex |
| Design approvals | EN 10204-3.1 |
| Hygienic approvals | 3-A, EHEDG |
The Nivector FTI26 is an economical level switch for powder applications in the food industry and various industries. The capacitive device has optimal anti-adhesion performance and extremely high sensitivity. It has certificates compliant with the standards of various industries. In addition, the FTI26 features IO-Link communication, meeting the requirements of Industry 4.0.
Advantages
Compact design for simple installation, even in confined spaces or hard-to-access applications
Meets all relevant hygienic requirements (3A, EHEDG, FDA, EG1935/2004); washdown-capable (IP69)
IO-Link reduces operating costs and operational complexity; the instrument can be configured conveniently via design software
Highest level of anti-adhesion performance and extremely high sensitivity
No need for separate adjustment for each medium
On-site function check via LED display
Application areas
For low-limit or high-limit detection of powdery and fine-grained bulk solids, e.g. plastic granules, grain, sugar, spices, coffee powder, washing powder
Process connection: G1" thread, Tri-Clamp 2" clamp
Temperature: -20...+80°C (-4...+176°F)
Pressure: -1...+6bar (-14.5...+86psi)
International explosion protection approval (dust explosion protection) and hygienic approval
E+H Product Model Configurator
Please enter the product model to configure
Product comparison
Please enter the product models to compare in the input fields below; up to three products can be compared
Technical documentation
Technical data
Documents / Manuals / Software
Accessories / Spare parts
Source:Endress+Hauserpublic information from the website
Case Studies
Municipal Wastewater Treatment — Wastewater Treatment Plant · Capacitance Application Case
Project Background
Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Capacitance.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage — Food Production Line · Capacitance Application Case
Project Background
Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Capacitance.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical — Reactors and Storage Tanks · Capacitance Application Case
Project Background
Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Capacitance.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy — Power Plant Boiler and Turbine · Capacitance Application Case
Project Background
Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Capacitance.
Solution
Based on the on-site conditions, the Ainstru technical team selected suitable Capacitance for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.
Results
- Measurement accuracy and response speed significantly improved, with stable and reliable data;
- Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
- Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Related Products
Endress+HauserLiquicap M FMI51
Endress+HauserMinicap FTC260
Endress+HauserSolicap M FTI55
Endress+HauserLiquicap M FMI52
Endress+HauserMinicap FTC262
Endress+HauserLiquicap M FTI51
Endress+HauserNivotester FTC325
Endress+Hauser