Instrumentation · Engineering · Package · PLC
0755-8222 1901 sales@ainstru.com

RN42 有源安全栅

RN42 有源安全栅

Active Barrier 24-230V AC/DC RN42

Configurable Models 3 models
The power supply isolator is used for transmission and galvanic isolation of 0/4 ... 20 mA/HART signals. The device has an active / passive current input to which a 2- or 4-wire transmitter can be connected directly. The output of the device can be operated actively or passively. The current signal is then available to the PLC / controller or for further instrumentation at pluggable screw or optional push-in terminals.
Compare

Power supplies & barrier

Measuring Principle Active barrier
Measuring principle Active barrier
Function 1-channel
Loop power supply 17,5 V ±1 V bei 20 mA
open circuit voltage: 24,5 V ±5 %
Power Supply ​24...230 V AC/DC
Input 0/4…20 mA / HART​
feeding/not feeding
Output 0/4…20 mA / HART​
active/passiv​e
Certificates ATEX Ex tc
CSA C/US AIS
JPN [Ex ia Ga], [Ex ia Da], Ex ec
KC [Ex ia Ga], [Ex ia Da], Ex ec
INMETRO [Ex ia Ga], [Ex ia Da], Ex ec
NEPSI [Ex ia Ga], [Ex ia Da], Ex ec
UK Ex tc, [Ex ia Ga], [Ex ia Da], Ex ec
ATEX IECEx [Ex ia Ga], [Ex ia Da], Ex ec
UL C/US
DNV
EAC [Ex ia Ga] IIC, [Ex ia Da] IIIC, Ex ec IIC Gc
SIL SIL 2 SC 3
Operation HART

The active barrier is used for transmitting and isolating 4...20 mA/HART signals. The device has an active or passive current input and can be connected directly to two-wire or four-wire transmitters. The device provides an active or passive output signal. The current signal is available to a PLC or controller, or to downstream devices via pluggable screw terminals or optional push-in terminals.

Advantages
Wide voltage range, 19.2...253 V AC/DC

Push-in terminals for fast and simple wiring

Can be used in SIL 2 (SC3) safety systems complying with IEC 61508

Optional installation for use in Zone 2 explosion-protected areas

Compact housing with a width of only 17.5 mm (0.69 in), making efficient use of space

Optional 180° rotated installation (power terminals facing up or down)


Field of application
Single-channel active barrier with wide voltage range

Transmits and galvanically isolates 0/4...20 mA analog signals

Can connect intrinsically safe [Ex ia] signals from hazardous area outputs

Bidirectional HART® signal transmission

Optional power supply for two-wire or four-wire devices 

Active or passive signal output

Ambient temperature range: -40…60°C (-40…140°F)

 

E+H product configurator

Please enter the product order code to configure

Product comparison

Please enter the order codes of the products you wish to compare in the fields below (up to three products)

 

   

Technical documentation

   

Technical data

 

 

Documents/Manuals/Software

 

 

Accessories/Spare parts

 

Source:Endress+Hauserpublic information from the website

Model Name
RN42-8L1AU+LA 有源安全栅
RN42-AA1AU 有源安全栅
RN42-AA1AU+LA 有源安全栅
Municipal Wastewater Treatment

Municipal Wastewater Treatment — Wastewater Treatment Plant · Power Supplies and Safety Barriers Application Case

Project Background

Municipal Wastewater Treatment customers at the Wastewater Treatment Plant stage have long faced the challenge of insufficient accuracy in effluent quality monitoring and instruments prone to contamination causing data drift, affecting compliance discharge, placing higher demands on the stability and measurement accuracy of Power Supplies and Safety Barriers.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Power Supplies and Safety Barriers for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Municipal Wastewater Treatment conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Food & Beverage

Food & Beverage — Food Production Line · Power Supplies and Safety Barriers Application Case

Project Background

Food & Beverage customers at the Food Production Line stage have long faced the challenge of high hygienic measurement requirements, with inline instruments needing to withstand CIP/SIP cleaning while maintaining stable accuracy, placing higher demands on the stability and measurement accuracy of Power Supplies and Safety Barriers.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Power Supplies and Safety Barriers for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Food & Beverage conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Chemical & Pharmaceutical

Chemical & Pharmaceutical — Reactors and Storage Tanks · Power Supplies and Safety Barriers Application Case

Project Background

Chemical & Pharmaceutical customers at the Reactors and Storage Tanks stage have long faced the challenge of highly corrosive media and complex conditions, requiring corrosion-resistant and explosion-proof instruments, placing higher demands on the stability and measurement accuracy of Power Supplies and Safety Barriers.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Power Supplies and Safety Barriers for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Chemical & Pharmaceutical conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.
Power & Energy

Power & Energy — Power Plant Boiler and Turbine · Power Supplies and Safety Barriers Application Case

Project Background

Power & Energy customers at the Power Plant Boiler and Turbine stage have long faced the challenge of unstable measurement under high temperature and pressure, with high maintenance and downtime costs, placing higher demands on the stability and measurement accuracy of Power Supplies and Safety Barriers.

Solution

Based on the on-site conditions, the Ainstru technical team selected suitable Power Supplies and Safety Barriers for the customer and delivered one-stop service covering selection, installation, commissioning and tuning.

Results

  • Measurement accuracy and response speed significantly improved, with stable and reliable data;
  • Instruments adapt to complex Power & Energy conditions, greatly reducing maintenance;
  • Helping customers achieve continuous online monitoring and cost reduction, highly recognized by customers.